652061
2
Zoom out
Zoom in
Previous page
1/4
Next page
D GBD GB
2
Read the operating instructions carefully
before using the product for the first time or
assembling it.
This control module is intended
- for installation in model railroad layouts.
- for connection to an authorized model
railroad transformer or an electrical control
system connected to one
- for operation in a dry area
Using the product for any other purpose is
not approved and is considered incorrect.
The manufacturer cannot be held respon-
sible for any damage resulting from the im-
proper use of this product; liability in such a
case rests with the user.
Using the product correctly
Important Information!Wichtige Hinweise!
Lesen Sie vor der ersten Benutzung des Pro-
duktes bzw. dessen Einbau diese Anleitung
aufmerksam durch.
Das Produkt richtig verwenden
Dieser Steuerbaustein ist bestimmt
- zum Einbau in Modelleisenbahnanlagen
- zum Anschluss an einen zugelassenen Mo-
dellbahntransformator bzw. an einer damit
versorgten elektrischen Steuerung
- zum Betrieb in trockenen Räumen
Jeder darüber hinausgehende Gebrauch gilt
als nicht bestimmungsgemäß. Für hieraus
resultierende Schäden haftet der Hersteller
nicht; das Risiko hierfür trägt allein der Be-
nutzer.
Die Steuermodule für Lichtsignale 5220 bis
5226 von dienen der einfachen
und vorbildgerechten Ansteuerung aller
-Standard-Lichtsignale. Durch be-
sondere Technik erfolgt der Wechsel zwi-
schen den einzelnen Signalbildern wie beim
Vorbild fließend (die LEDs glimmen nach).
Die Signale werden direkt an den Steuermo-
dulen angeschlossen.
Darum, wie dann jeweils die einzelnen LEDs
der Lichtsignale angesteuert werden, brau-
chen Sie sich keine Gedanken mehr zu ma-
chen!
Das
Viessmann
Viessmann
Steuermodul für Licht-Ausfahrsignale
5223 wird über Taster (z.B. 5545
oder 5547), Gleiskontakte (z.B.
6840 für Baugröße H0) oder Schaltgleise an-
gesteuert.
Über die Buchsen "Vorsignal-Steuerung"
Viessmann
Viessmann
The control modules for colour light signals
5220 to 5226 by are designed to
provide a simple means for prototypical con-
trol of all standard colour light
signals. Special circuitry enables prototypical
transition between signal aspects by first
dimming and then turning off the LED with
subsequent soft start of the LED of the new
signal aspect. The signals shall be connec-
ted directly to the control modules.
That's why you don't have to worry about
how each individual LED of a colour light
signal is controlled.
The control module for colour light exit signal
5223 can be operated with momentary action
switches or bell press (e.g. 5545
or 5247), track contacts (e.g.
6840 for H0 gauge) or switching tracks.
Viessmann
Viessmann
Viessmann
Viessmann
A control module 5220 for a colour light dis-
Warning!
All connection and installation work
must be performed with the operating
voltage switched off!
The power source must be protected so
that no cable fire can occur if there is a
short circuit. Use model railroad
transformers built in compliance with
VDE/EN only.
Achtung!
Alle Anschluss- und Montagearbeiten
sind nur bei abgeschalteter Betriebs-
spannung durchzuführen!
Die Stromquellen müssen so
abgesichert sein, dass es im Falle eines
Kurzschlusses nicht zum Kabelbrand
kommen kann. Verwenden Sie nur nach
VDE/EN gefertigte
Modellbahntransformatoren!
Einleitung Introduction
mind. 1 Zuglänge
minimum 1 train length
Sie können das Steuermodul für Licht-Aus-
fahrsignale auch mit einem Digitalsystem
über einen Magnetartikeldecoder (z.B. -
5211 für Märklin-Motorola-Format oder
5212 für das NMRA-DCC-Format) ansteuern
(Abbildung 8). Wichtig ist, dass der Magnet-
artikeldecoder positive Schaltimpulse liefert
(d.h. er schaltet gegen "+")! Außerdem muss
beim 5211 eine Verbindung zwischen Digital-
Masse (braun) und Masse der 16V-Versor-
gungsspannung des Steuermoduls (braun)
hergestellt werden. Beim 5212 muss hinge-
gen die Masse der separaten Spannungsein-
speisung ("~" ohne "E") mit der Masse des
Steuermoduls (braun) verbunden werden.
Alternativ können sie auch das Digitalsteuer-
modul für Licht-Ausfahrsignale
5226 verwenden. Dort ist ein Digitaldecoder
bereits integriert!
Viess
mann
Viessmann
braun brown
rot red
Digitale Ansteuerung Digital Control
7
The control module for colour light exit sig-
nals also be operated with a digital system.
Simply connect the wires to an accessory
decoder (e.g. 5211 for Marklin-
Motorola format or 5212 for the NMRA DCC
format). Also refer to figure 8. It is important
to know, that the pulses supplied by the ac-
cessory decoder have positive potential (the
decoder switches against “+”)! With the 5211
the common pole of the digital circuit (brown)
must be connected with the common pole of
the 16 V supply for the control module
(brown). Whereas with the 5212 the common
of the separate power supply (“~” without
“E”) has to be connected with the common
pole of the control module (brown).
Alternately you can use the 5226
digital control module for color light exit sig-
nals. It has got an integral digital decoder.
Viessmann
Viessmann
Abbildung 7 Figure 7
direction
of travel
5223
ca. 2
Loklängen
approx. 2
locomotive
lengths
gelb
yellow
16 V~
AC
schwarze
Markierung
black marking
gelbe Markierung yellow marking
Diode
diode
grüner Stecker green plug
Fahrstrom
propulsion
current
rot red
rot red
rote Stecker
red plugs
rote Markierungen red markings
grüner Stecker green plug
braun brown
gelber Stecker
yellow plug
grüne Markierung green marking
gelber Stecker yellow plug
roter Stecker red plug
Fahrtrichtung
blau blue
5545
viessmann
5545
Stellpult für Ausfahrsignale
Hp0 Hp1
Sh1 Hp2
braun brown
gelber Stecker
yellow plug
grüner Stecker
green plug
Hp0
Hp2
weißer Stecker
white plug
blau blue
gelb yellow
Schaltgleise oder Gleiskontakte
(z.B. 6840) schalten das
Signal automatsch zurück auf Hp0
("Halt")
Viessmann
switching tracks or track contacts
(e.g. 6840) switch the
signal back to Hp0 ("stop")
automatically
Viessmann
blau blue
geradeaus
straight on
abzweigen
branch off
rt1
ws
zum Gleis
gn
Vorsignal -
Steuerung
rt2
viessmann
Steuermodul für
Licht-Ausfahrsignal
5223
16 V
bn ge
ge
weißer Stecker white plug
weiße Markierung white marking
weißer Stecker white plug
blau blue
roter Stecker
red plug
1 A - Dioden (z.B. -
6834, 10 Stück)
-
Viess
mann
Viess
mann
1 Amp. diodes (e.g.
6834, 10 pieces)
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Viessmann 5223 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Viessmann 5223 in the language / languages: English, German as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info