785407
8
Zoom out
Zoom in
Previous page
1/145
Next page
6
3. Installation
WARNING: DC (PV) INPUT NOT ISOLATED FROM BATTERY CIRCUIT.
CAUTION: FOR PROPER TEMPERATURE COMPENSATION
THE AMBIENT CONDITION FOR CHARGER AND BATTERY MUST BE
WITHIN 5°C.
3.1 General
Mount vertically on a non-flammable surface, with the power terminals
facing downwards. Observe a minimum clearance of 10 cm under and above
the product for optimal cooling.
● Mount close to the battery, but never directly above the battery (in order to
prevent damage due to gassing of the battery).
● Improper internal temperature compensation (e.g. ambient condition
battery and charger not within 5°C) can lead to reduced battery lifetime.
We recommend installing the Smart Battery Sense option if larger
temperature differences or extreme ambient temperature conditions
are expected.
● Battery installation must be done in accordance with the storage battery
rules of the Canadian Electrical Code, Part I.
● The battery connections (and for Tr version also PV connections) must be
guarded against inadvertent contact (e.g. install in an enclosure or install the
optional WireBox).
Tr models: use flexible multistranded copper cable for the battery and PV
connections: see safety instructions.
MC4 models: several splitter pairs may be needed to parallel the strings of
solar panels. (Maximum current through a MC4 terminal: 30A)
3.2 Grounding
Battery grounding: the charger can be installed in a positive or negative
grounded system.
Note: apply a single ground connection (preferably close to the battery) to
prevent malfunctioning of the system.
Chassis grounding: A separate earth path for the chassis ground is
permitted because it is isolated from the positive and negative terminal.
The USA National Electrical Code (NEC) requires the use of an external
ground fault protection device (GFPD). These MPPT chargers do not have
internal ground fault protection. The system electrical negative should be
bonded through a GFPD to earth ground at one (and only one) location.
● The charger must not be connected with grounded PV arrays. (one ground
connection only)
● The plus and minus of the PV array should not be grounded. Ground the
frame of the PV panels to reduce the impact of lightning.
WARNING: WHEN A GROUND FAULT IS INDICATED, BATTERY
TERMINALS AND CONNECTED CIRCUITS MAY BE UNGROUNDED
AND HAZARDOUS.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SmartSolar MPPT 250 85 MC4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SmartSolar MPPT 250 85 MC4 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info