Using the pluggable LCD display or VictronConnect and the procedures
below, most errors can be quickly identified. If an error cannot be resolved,
please refer to your Victron Energy supplier.
Error nr.
Problem
Cause / Solution
n. a.
The LCD does not light up
(no backlight, no display)
The internal power supply used for powering
the converter and the backlight is derived from
either the solar-array or the battery.
If PV and battery voltage are both below 6V
the LCD will not light up. Make sure that the
LCD display is properly inserted into the
socket.
n. a.
The LCD does not light up
(backlight works, no display,
charger seems to work)
This may be due to low ambient temperature.
If the ambient temperature is below -100C
(140F) the LCD-segments can become vague.
Below -200C (-40F) the LCD-segments can
become invisible.
During charging the LCD-display will warm up,
and the screen will become visible.
n. a.
The charge controller does
not charge the battery
The LCD-display indicates that the charge-
current is 0 Amps.
Check the polarity of the solar-panels.
Check the battery breaker
Check if there is an error indication on the LCD
Check if the charger is set to "ON" in the
menu.
Check if the Remote input is connected.
Check if the right system voltage has been
selected
n. a.
High temperature: the
thermometer icon blinks
This error will auto-reset after temperature has
dropped.
Reduced output current due to high
temperature.
Check the ambient temperature and check for
obstructions near the heatsink.
Err 2
Battery voltage too high
(>76,8V)
This error will auto-reset after the battery
voltage has dropped.
This error can be due to other charging
equipment connected to the battery or a fault
in the charge controller.
Err 17
Controller overheated
despite reduced output
current
This error will auto-reset after charger has
cooled down.
Check the ambient temperature and check for
obstructions near the heatsink.
Err 18
Controller over-current
This error will auto-reset.
Disconnect the charge controller from all
power-sources, wait 3 minutes, and power up
again.
If the error persists the charge controller is
probably faulty.
Err 20
Maximum Bulk-time
exceeded
This error can only occur when the maximun
bulk-time protection is active. This error will not
auto-reset.
This error is generated when the battery-
absorption-voltage is not reached after 10
hours of charging.
For normal solar installations it is advised not
to use the maximum bulk-time protection.
Err 21
Current sensor issue
The charge controller is probably faulty.
This error will not auto-reset.
Err 26
Terminal overheated
Power terminals overheated, check wiring and
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SmartSolar MPPT 150 60 MC4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SmartSolar MPPT 150 60 MC4 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info