785401
10
Zoom out
Zoom in
Previous page
1/145
Next page
8
3.6 Configuration of the controller with the rotary switch
Fully programmable charge algorithm (see the software page on our
website) and eight preprogrammed charge algorithms, selectable with a
rotary switch:
Pos
Absorption
V
Float
V
Equalize
V
@%Inom
dV/dT
mV/°C
0
Gel Victron long life (OPzV)
Gel exide A600 (OPzV)
Gel MK
28,2 27,6
31,8
@8%
-32
1 Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
28,6 27,6
32,2
@8% -32
2
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
28,8 27,6
32,4
@8% -32
3
Stationary tubular plate (OPzS)
29,4
27,6
33,0
@8%
-32
4
29,8
27,6
33,4
@25%
-32
5
OPzS batteries
30,2
27,6
33,8
@25%
-32
6
PzS tubular plate traction batteries or
30,6
27,6
34,2
@25%
-32
7
4
28,4 27,0 n.a. 0
Note 1: divide all values by two in case of a 12V system and multiply by two
in case of a 48V system.
Note 2: equalize normally off, see sect. 3.9 to activate
(do not equalize VRLA Gel and AGM batteries)
Note 3: any setting change performed with the pluggable LCD display or via
Bluetooth will override the rotary switch setting. Turning the rotary switch will
override prior settings made with the pluggable LCD display or via Bluetooth.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SmartSolar MPPT 150 60 MC4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SmartSolar MPPT 150 60 MC4 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info