● Use cable de cobre multifilamento flexible para las conexiones FV
y de la batería. El diámetro máximo de cada filamento es
0,4 mm/0,125 mm² (0,016 pulgadas/AWG26).
Por ejemplo, un cable de 25 mm², deberá tener al menos 196 filamentos
(filamento de clase 5 o superior según las normas VDE 0295, IEC 60228 y
BS6360).
Un cable de calibre AWG2 deberá tener al menos un trenzado de 259/26
(259 filamentos de AWG26).
Temperatura máxima de trabajo: ≥ 90°C.
Ejemplo de cable adecuado: cable de triple homologación de clase 5
(cumple tres normativas): la americana (UL), la canadiense (CSA) y la
británica (BS)).
Si los filamentos usados son más gruesos, la zona de contacto será
demasiado pequeña y la alta resistencia del contacto resultante
puede producir un fuerte sobrecalentamiento que podría causar un
incendio.
Corriente máxima a través de un terminal MC4: 30A
103


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SmartSolar MPPT 150 45-Tr at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SmartSolar MPPT 150 45-Tr in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info