5. Specifications, 150V models
SmartSolar charge controller
MPPT
150/45
MPPT
150/60
MPPT
150/70
Battery voltage
12/24/48V Auto Select (36V: manual)
Maximum battery current
45A
60A
70A
Nominal PV power, 12V 1a,b)
650W
860W
1000W
Nominal PV power, 24V 1a,b)
1300W
1720W
2000W
Nominal PV power, 36V 1a,b)
1950W
2580W
3000W
Nominal PV power, 48V 1a,b)
2600W
3440W
4000W
Max. PV short circuit current 2)
50A (max 30A per MC4 conn.)
Maximum PV open circuit voltage
150V absolute maximum coldest conditions
145V start-up and operating maximum
Peak efficiency
98%
Self consumption
Less than 35mA @ 12V / 20mA @ 48V
Charge voltage 'absorption'
Default setting: 14,4V / 28,8V / 43,2V / 57,6V
( dj bl )
Charge voltage 'float'
Default setting: 13,8V / 27,6V / 41,4V / 55,2V
Charge voltage 'equalization'
Default setting: 16,2V / 32,4V / 48,6V / 64,8V
Charge algorithm
multi-stage adaptive (eight preprogrammed
algorithms) or user defined algrithm
Temperature compensation
-16mV/°C / -32mV/°C / -64mV/°C
Protection
Battery reverse polarity (fuse, not user accessible)
PV reverse polarity / Output short circuit / Over
temperature
Operating temperature
-30 to +60°C (full rated output up to 40°C)
Humidity
95%, non-condensing
Maximum altitude
5000m (full rated output up to 2000m)
Environmental condition
Indoor, unconditioned
Pollution degree
PD3
Data communication port
VE.Direct or Bluetooth
Remote on/off
Yes (2 pole connector)
Relay (programmable)
DPST AC rating: 240VAC / 4A DC rating: 4A up to 35VDC, 1A up to
60VDC
Parallel operation
Yes (not synchronized)
ENCLOSURE
Colour
Blue (RAL 5012)
PV terminals 3) 35 mm² / AWG2 (Tr models)
or dual MC4 connectors (MC4 models)
Battery terminals
35 mm² / AWG2
Protection category
IP43 (electronic components) IP22 (connection area)
Weight
3 kg
Dimensions (h x w x d)
Tr models: 185 x 250 x 95 mm
MC4 models: 215 x 250 x 95 mm
STANDARDS
Safety
EN/IEC 62109-1, UL 1741, CSA C22.2
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher short circuit current may damage the controller in case of reverse
polarity connection of the PV array.
3) Default setting: OFF
4) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SmartSolar MPPT 150 45-Tr at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SmartSolar MPPT 150 45-Tr in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info