5. Especificaciones
Controlador de carga SmartSolar
MPPT 100/30
MPPT 100/50
Tensión de la batería AutoSelect 12/24 V
Corriente máxima de la batería 30A 50A
Potencia FV nominal, 12V 1a,b) 440W 700W
Potencia FV nominal, 24V 1a,b) 880W 1400W
Tensión máxima del circuito abierto
FV
100V 100V
Max. corriente de cortocircuito PV 35A 60A
Eficiencia máxima
98%
98%
Autoconsumo 10 mA
Tensión de carga de "absorción" Valores predet.: 14,4V / 28,8V (ajustable)
Tensión de carga de
«ecualización" 3
Valores predet.: 16,2V / 28,8V (ajustable)
Tensión de carga de "flotación" Valores predet.: 13,8V / 27,6V (ajustable)
Algoritmo de carga
Variable multietapas (ocho algoritmos
preprogramados) o algoritmo definido por el usuario
Compensación de temperatura
-16 mV / °C resp. -32 mV / °C
Protección
Polaridad inversa de la batería (fusible, no accesible
por el usuario)
Cortocircuito de salida
Sobretemperatura
Temperatura de trabajo
-30 a +60°C (potencia nominal completa hasta los
40°C)
Humedad 95 %, sin condensación
Altura máxima de trabajo
5.000 m
(potencia nominal completa hasta los 2.000 m)
Condiciones ambientales
Para interiors Tipo 1, no acondicionados
Grado de contaminación
PD3
Puerto de comunicación de datos y
on/off remoto
VE.Direct
Consulte el libro blanco sobre comunicación de datos
en nuestro sitio web
CARCASA
Color
Azul (RAL 5012)
Terminales de conexión
16 mm² / AWG6
Tipo de protección
IP43 (componentes electrónicos)
IP 22 (área de conexiones)
Peso
1,25 kg.
Dimensiones (al x an x p)
130 x 186 x 70 mm
ESTÁNDARES
Seguridad
EN/IEC 62109-1, UL 1741, CSA C22.2
1a) Si se conecta más potencia FV, el controlador limitará la entrada de potencia.
1b) La tensión FV debe exceder Vbat + 5V para que arranque el controlador.
Una vez arrancado, la tensión FV mínima será de Vbat + 1V.
2) Una corriente de cortocircuito más alta podría dañar el controlador en caso de polaridad inversa de
la conexión de los paneles FV.
3) Valores predeterminados: OFF
69


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SmartSolar MPPT 100 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SmartSolar MPPT 100 50 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info