PV voltage must exceed Vbat + 5V for the controller to start. Thereafter minimum PV
voltage is Vbat + 1V.
Maximum open circuit PV voltage: 75V respectively 100V
For example:
12V battery and mono- or polycristalline panels connected to a 75V controller
Minimum number of cells in series: 36 (12V panel).
Recommended number of cells for highest controller efficiency: 72
(2x 12V panel in series or 1x 24V panel).
Maximum: 108 cells (3x 12V panel in series).
24V battery and mono- or polycristalline panels connected to a 100V controller
Minimum number of cells in series: 72
(2x 12V panel in series or 1x 24V panel).
Maximum: 144 cells (4x 12V panel in series).
Remark: at low temperature the open circuit voltage of a 108 cell array may exceed 75V
and and the open circuit voltage of a 144 cell solar array may exceed 100V, depending on
local conditions and cell specifications. In that case the number of cells in series must be
reduced.
3.4 Cable connection sequence (see figure 4 at the end of this manual)
First: connect the cables to the load, but ensure that all loads are switched off.
Second: connect the battery (this will allow the controller to recognize system voltage).
Third: connect the solar array (when connected with reverse polarity, the controller will heat
up but will not charge the the battery).
The system is now ready for use.
3.5. Configuration of the controller (see figure 1 and 2 at the end of this manual)
If a Bluetooth device or other means of communication is not available, the VE.Direct
communication port (see section 1.9) can be used to configure the load output as follows:
3.6 The load output
The load out output can be configured with Bluetooth or via VE.Direct.
Alternatively, a jumper can be used to to configure the load output as follows:
3.6.1. No jumper: BatteryLife algorithm (see 1.5.)
3.6.2. Jumper between pin 1 and pin 2: conventional
Low voltage load disconnect: 11,1V or 22,2V
Automatic load reconnect: 13,1V or 26,2V
3.6.3. Jumper between pin 2 and pin 3: conventional
Low voltage load disconnect: 11,8V or 23,6V
Automatic load reconnect: 14V or 28V
Note: remove the jumper when using Bluetooth to configure the controller
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SmartSolar MPPT 100 20-48V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SmartSolar MPPT 100 20-48V in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info