5. FAULT TRACING
When a fault occurs in the battery charger, the following table can be used in order to find the
fault. Before the Titan is being checked, make sure that all the devices connected to the
battery charger are removed. If the fault can not be solved contact your Victron Energy dealer.
Problem Possible cause Solution
The charger does not
operate
The mains voltage has to be in between
185Vac and 265 Vac.
Measure the mains voltage and make sure it is in
between 185Vac and 265Vac.
A broken input fuse. Return the charger to your dealer.
The battery is not
being fully charged
The equalize-charge mode is set to
a too short period.
Set the equalize-charge mode to a longer time.
A bad battery connection. Check the battery connections.
The boost charge voltage is
set to a wrong value.
Adjust the boost charge voltage to the right
value.
The float charge voltage is
set to a wrong value.
Adjust the float charge voltage to the right
value.
The capacity of the battery is too large.
Connect a battery with a smaller capacity or
install a larger charger.
The output fuses are broken. Replace the output fuses.
The battery is being
overcharged
The battery charger is set into the
permanent boost-charge mode.
Deselect the permanent boost DIP-switch
(Rboost).
The boost charge voltage is
set to a wrong value.
Adjust the boost charge voltage to the right
value.
The float charge voltage is
set to a wrong value.
Adjust the float charge voltage to right value.
A bad battery. Check the battery.
The battery is located in a warm place Connect a temperature sensor
The battery is too small. Reduce the charge current.
The failure led
illuminates
The charger is switched off as a result
of a high ambient temperature.
Place the charger in a cooler, or better ventilated
place.
The failure led
flashes
The charger is reducing the output
current as a result of a high ambient
temperature.
Place the charger in a cooler, or better ventilated
place.
The failure led
flashes in a code
1
The output fuses are broken. Replace the output fuses.
The failure led
illuminates in
combination with a
blinking on/off led
There is a voltage drop higher than 2V
across the battery cables.
Turn the charger off, replace battery cables and
connect them well.
1
Flashing code sequence is two times on in one second and then one second off.
A qualified technician may only remove the cover of the Titan. Before
obtaining access to the Titan the mains supply circuit must be
disconnected.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Skylla-TG 48 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Skylla-TG 48 50 in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 0.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info