Manual Titan
4.1 Permanent boost-charge
In some cases, for example when the battery is almost empty, it is recommended to permanent
boost-charge the battery for 10 hours. Do not permanently boost-charge sealed lead-acid
batteries. Contact your Victron Energy dealer or battery dealer for more information on
charging the battery.
To set the charger into the permanent boost-charge mode :
Place the DIP switch number 8 “R boost” to the left. In this mode the
battery is being charged to the boost voltage.
Do not permanent boost-charge the battery for longer than 10 hours as
this can cause long term gas formation in the battery and will damage
the battery.
While a battery is being boost-charged, check the water level of the
battery frequently and if necessary add distilled water to the battery.
4.2 Adjusting the charge voltage
The battery charger has a factory set float and boost voltage. The boost-voltage is always
higher than the float-voltage. These charging voltages are the recommended values from
almost every battery manufacturer. Before adjusting the charge voltage disconnect the
temperature sensor and/or the voltage sense wires.
To change the float-voltage:
Remove all batteries and other users that are connected to the output of
the battery charger.
Plug the AC plug into the mains and switch on the charger.
Place DIP-switches 7 “Eq2and 6 “Eq1” to the left position, this will
reduce the equalize time to 0 hours. The charger switches into the
float-charge mode.
Place DIP-switch 4 “fine” to the left position in order to accurately
adjust the output voltage.
Measure the float-voltage on the charger output by using a precision
voltage meter.
Adjust the float-voltage by turning the “V floatpotentiometer until the
recommended voltage is reached.
Correct the equalize time by moving DIP-switch 7 “Eq2” and 6 “Eq1”.
Place DIP-switch 4 fine” to the right position. In this position the
output voltage is less sensitive to influence of temperature.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SKYLLA-TG 24 100 3-Phase at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SKYLLA-TG 24 100 3-Phase in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 0.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info