11
3. DIRECTIONS FOR USE
3.1 Installation
Find a dry and well-ventilated area to mount the Titan charger and battery. Keep the distance
between the charger and the battery less than 6 meters.
The charger may be wall or floor mounted. Mounting on a wall improves the air circulation
within the charger cabinet and will prolong the lifetime of the battery charger.
The holes for the mains cable, the battery connections, the remote connections and the earth
connection are located at the bottom of the battery charger housing, see illustration 2.
M6 Earth
Stud
Hole for the
mains cable Hole for the starter
battery cables
Hole for the
remote cable
Hole for the
positive
battery cable
Hole for the
negative
battery cable
Connecting earth
Connect the earth screw to a real earth-point. Connections to earth have to be according to
applicable safety standards.
On a ship: Connect the earth screw to the earth plate or to the hull of the ship.
On land: Connect the earth screw to the earth of the mains.
Mobile applications (a vehicle, a car or a caravan): Connect the earth screw to the frame
of the vehicle.
v
Connecting the battery
The connections between the Titan charger and the battery are essential for a good operation
of the charger. Therefore the battery connections need tightening well. It is important to use
short and thick battery cables to minimise the voltage losses in the cable. Cable resistance
decreases accordingly as the cables become shorter and thicker. Therefore it is not
recommended to use cables longer than 6 meters. The table below shows the recommended
cable core thickness.
Type core diameter of cables until 1,5m core diameter of cables between 1,5m and 6m
24/80 16 mm
2
25 mm
2
24/100 35 mm
2
50 mm
2
24/100 3-Ph 35 mm
2
50 mm
2
48/50 10 mm
2
16 mm
2
Illustration 2,
Location of the charger
connection holes
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron SKYLLA-TG 24 100 3-Phase at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron SKYLLA-TG 24 100 3-Phase in the language / languages: English, German, Dutch as an attachment in your email.

The manual is 0.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info