4.13. Automatic voltage compensation
The charger compensates for the voltage drop over the DC cables by gradually
increasing the output voltage if the charging current rises.
The fixed voltage offset is 100mV. The voltage offset is scaled with the charge
current and added to the output voltage. The voltage offset is based on 2x 1-
meter cable, contact resistance and fuse resistance.
Example calculation for the 12/50 (1+1):
The cable resistance R can be calculated with the following formula:
=×
Here R is the resistance in ohms (Ω), ρ is the resistivity of copper (1.786x10^-8
Ωm at 25°C), l is the wire length (in m) and A is the surface area of the wire (in
m²).
A widely used distance from charger to battery is 1 metre. In this case the wire
length is 2 metres (plus and minus). When using a 6AWG cable (16mm²) the
wire resistance is:
 =1,786 ×10−8 × 2
16 ×10−6 = 2.24Ω
Installing a fuse close to the battery is highly recommended. The resistance of a
standard 80A fuse is:
 = 0.720Ω
The overall resistance of the circuit can then be calculated with the following
formula:
 = +
Therefore:
 = 2.24Ω + 0.720Ω = 2.96Ω
The required voltage drop compensation over the cable can be calculated with
the following formula:
=×
In which U is the voltage drop in volts (V) and I is the current through the wire in
amperes (A).
The voltage drop will then be:
=50 × 2.96Ω =148 for the full 50A charging current.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix Smart lader 24 16 (1 1) IP43 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix Smart lader 24 16 (1 1) IP43 in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 0.78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info