6.2 Omvormer
12/800
/ 35
12/1200
/ 50
12/1600
/ 70
24/800
/ 16
24/1200
/ 25
24/1600
/ 35
48/1200
/ 12
48/1600
/ 20
12/800 12/1200 12/1600 24/800 24/1200 24/1600 48/1200 48/1600
Ingangsspanning-
bereik (Vdc)
9,5 -16,1 19,0 - 32,2
38,0 - 64,4
Inschakelspanning
(Vdc)
10,9 21,8
43,6
Uitschakel-
spanninglaag
(Vdc)
9,0 18,0
56
Uitschakel-
spanning hoog
(Vdc)
16,1 32,2
64,4
rimpelspanning
(Vrms)
Max. 1,25Vrms
Ingangsstroom
Nominaal (A)
65 100 130 35 50 65 25 35
Ingangsstroom
Maximaal (A)
85 130 170 40 65 85 30 40
Vermogens-
verbruik onbelast
(W)
8 8 8 12 12 12 15 15
Economy 5 5 5 9 9 9 12 12
DC veiligheids-
zekering (A)
200 250 250 150 200 200 150 150
Output (Vac) 230 ± 1%
Output Voltage
Range (Vac)
185–245
Frequentie (Hz) 50/60 ±0,01% (kristal)
Uitgangs-spanning Pure sinwave
THD Max. 5%
Arbeidsfactor Alles toegestaan
Economy DS6=on
load < +/- 25W
145VAC top=300V
speciaal aangepast voor SL- PL- and TL lampen (normale lichtsterkte)
and klokken
Geen lineaire
belasting, crest
factor 3:1 (VA)
25ºC)
800 1200 1600 800 1200 1600 1200 1600
Nominaal
vermogen (W)
(cos
ϕ
= 1,0; 25ºC)
650 1000 1300 650 1000 1300 1000 1300
Nominaal
vermogen (W)
(cos ϕ = 1,0; 40ºC)
600 900 1100 600 900 1100 900 1100
Opstart vermogen
(W)
1900 2000 2300 1900 2600 3000 2600 3000
Inschakelgedrag De nominale uitgangsspanning is aanwezig binnen 20mS
Rendement Pnom 87% 86% 84% 88% 87% 86% 87% 86%
efficiency
½ Pnom
90% 88% 87% 90% 89% 87% 90% 88%
kortsluitstroom 10 12 13 10 12 13 13 15
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix MultiPlus Compact at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix MultiPlus Compact in the language / languages: Dutch as an attachment in your email.

The manual is 0,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info