6. MAINTENANCE
The Phoenix Inverter does not require specific maintenance. It will suffice to check all
connections once a year. Avoid moisture and oil/soot/vapours, and keep the device
clean.
7. FAULT INDICATIONS
With the procedures below, most errors can be quickly identified. If an error cannot be
resolved, please refer to your Victron Energy supplier.
7.1 General error indications
Problem
Cause
Solution
Inverter operation not
initiated when
switched on.
The battery voltage is excessively
high or too low. No voltage on DC
connection.
Ensure that the battery voltage is
within the correct range.
“Low battery” LED
flashes.
The battery voltage is low.
Charge the battery or check the
battery connections.
“Low battery” LED
lights.
The converter switches off
because the battery voltage is too
low.
Charge the battery or check the
battery connections.
“Overload” LED
flashes.
The converter load is higher than
the nominal load.
Reduce the load.
“Overload” LED
lights.
The converter is switched off due
to excessively high load.
Reduce the load.
“Temperature” LED
flashes or lights.
The environmental temperature is
high, or the load is too high.
Install the converter in cool and
well-ventilated environment, or
reduce the load.
“Low battery” and
“overload” LEDs
flash intermittently.
Low battery voltage and
excessively high load.
Charge the batteries, disconnect
or reduce the load, or install
higher capacity batteries. Fit
shorter and/or thicker battery
cables.
“Low battery” and
“overload” LEDs
flash simultaneously.
Ripple voltage on the DC
connection exceeds 1,5Vrms.
Check the battery cables and
battery connections. Check
whether battery capacity is
sufficiently high, and increase
this if necessary.
“Low battery” and
“overload” LEDs
light.
The inverter is switched off due to
an excessively high ripple voltage
on the input.
Install batteries with a larger
capacity. Fit shorter and/or
thicker battery cables, and reset
the inverter (switch off, and then
on again).
One alarm LED lights
and the second
flashes.
The inverter is switched off due to
alarm activation by the lighted
LED. The flashing LED indicates
that the inverter was about to
switch off due to the related alarm.
Check this table for appropriate
measures in regard to this alarm
state.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix Inverter Compact 48 5000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix Inverter Compact 48 5000 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info