4.3 Conexión del cableado CA
El conector del terminal de salida de la red se ubica en la parte inferior del Inverter Compact,
ver Apéndice A. El cable del pantalán o de red eléctrica deberá conectarse al conector con un
cable de tres hilos.
Procedimiento
El cable de salida CA puede conectarse directamente al conector macho. (¡el conector sale
tirando de él!
Los puntos de terminal están claramente indicados. De izquierda a derecha: “N” (neutro),
tierra, y “L1” (fase).
Introduzca el conector de “salida” en el conector “AC-out” (cerca de la parte trasera).
4.4 Opciones de conexión
Existen varias opciones de conexión distintas:
4.4.1 Panel de control remoto y conmutador on/off remoto
El producto puede manejarse de forma remota de dos maneras:
- Con un conmutador externo (terminal de conexión H, ver apéndice A). Sólo funciona si el
conmutador del inversor está en “on”.
- Con un panel deControl Phoenix Inverter (conectado a una de las dos tomas RJ48 C, ver
apéndice A). Sólo funciona si el conmutador del inversor está en “on”.
Sólo se puede conectar un control remoto, es decir, o bien un conmutador o un panel
de control remoto.
4.4.2. Relé programable
Los inversores disponen de un relé multifuncional programado por defecto como relé de
alarma. (Se necesita el software del VEConfigure para cambiar la función del relé).
Cuando se activa el relé, se ilumina un LED situado al lado de los terminales de conexión
(consulte S, ver apéndice A).
Este producto es un dispositivo de clase de seguridad I (suministrado con
terminal de puesta a tierra).
El cable neutro de la salida CA de este inversor está conectado al
chasis.
Con esto se garantiza el funcionamiento correcto del GFCI (o RCCB) que
deberá instalarse en la salida AC del inversor.
El chasis de este producto debe conectarse a tierra, al chasis (de un
vehículo) o a una placa de toma de tierra o al casco (de un barco).
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix Inverter Compact 12 1200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix Inverter Compact 12 1200 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1.62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info