785489
48
Zoom out
Zoom in
Previous page
1/96
Next page
47
victron energy
Justeringer uden fjernstyringspanel
ADVARSEL: Kontrollér altid hos Deres
batterileverandør, om den valgte
opladningskarakteristik er egnet til Deres
batteri og anvendelse
Fjern frontpladen og afbryd batteriet,
spændingsfølingen, og temperaturføleren, og
forbind et digitalt voltmeter til – og +1 udgangen.
Bulk-strøm
Når der tændes holdes begge disse trykknapper
&
nede.
Slip trykknapperne.
Bulk LED displayet blinker skiftevist med Failure
LED displayet.
Tryk
for op og
for ned.
Aflæs følgende:
Se bort fra første ciffer i DVM og gang derefter
med 10, d.v.s.:
22.50V => ….2.50 => 25 Amp
15.00V => .…5.00 => 50 Amp
Sluk for opladeren (Off) for at gemme.
Absorptions og Float spænding
Mens der tændes holdes trykknappen
nede
for Absorptions-spænding og
for Float-
spænding.
Slip trykknapperne.
Absorptions eller Float LED displayet blinker
skiftevist med Failure LED displayet.
Tryk
for op og
for ned.
Aflæs voltmeteret som det er.
Sluk for opladeren (Off) for at gemme.
Bemærk venligst, at i justerings-indstillingen
tages der ikke hensyn til temperaturfølings-
kompensation.
Advarsel: Hvis opladeren ikke slukkes (Off)
efter en justering, vil den nye værdi ikke blive
gemt, men forblive på udgangene. Efter 4
timer fortsætter opladeren sine normale
sekvenser med de gamle værdier. Dette kan
være nyttigt, hvis en fremprovokeret høj
spænding er ønskelig for at få liv i et formodet
”dødt” batteri.
Genetablering af fabriksindstillinger
Tænd for opladeren.
Hold trykknappen
og/eller
trykket ned mens
der slukkes (
Off
).
Fabriksindstillingerne er genetablerede.
Når opladeren er klar
Forbind batteriet og, hvis anvendt,
spændingsfølingen og temperaturføleren.
Sæt frontpladen på igen.
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Justering, maksimal Bulk strøm
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Justering, Float spænding
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Justering, Absorptions-spænding
20AT
20AT
20AT
20AT
PE earth connection
N AC input : Neutral
L AC input : Line
+ battery 1
+ battery 2
- battery
+ Trickle charge
- Trickle charge
+ Voltage sense
- Voltage sense
+ Temperature sense
- Temperature sense
Remote
co
nnector
<= =>
Genetablering, standardværdier
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix acculader 12 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix acculader 12 30 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 1.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info