785489
6
Zoom out
Zoom in
Previous page
1/96
Next page
5
victron energy
INSTALLATION
WARNING: Qualified personnel only
Location
The Phoenix Charger must be installed in a dry,
well-ventilated area.
Too high an ambient temperature has the
consequence of lower output, shorter life or a
complete shutdown of the Phoenix Charger.
The Phoenix Charger is suitable for floor and wall
mounting. However, for optimum cooling, a
vertical position is recommended. The cables
between the Phoenix Charger and the battery
must be kept as short as possible to minimise
cable losses.
Required tools and cables
Socketdriver & socket 10 mm.
Screwdriver no. 2.
Crosshead screwdriver no. 2 phillips.
Battery cables and external fuse:
Model
Length 0
-
6 m
Fuse
12/30 16 mm² 40 AT
12/50 25 mm² 60 AT
24/16 10 mm² 20 AT
24/25 16 mm² 30 AT
Cables longer then 6 m are not recommended.
Cable eyes with M6 holes should be used.
For supply connection use wires suitable for at
least 75°C (167°F).
CAUTION: Replace defective cords or wires
immediately.
Connection sequence
Disconnect mains.
Disconnect battery cables from the battery.
Remove the frontplate.
Remove carfuses if placed.
Connect the housing of the charger to ground.
The housing is fitted with an M4 ground screw for
this purpose.
Connect the accompanying temperature sensor
to the +T-sense and –T-sense and mount the M8
cable-eye to one of the battery clamps. The
connector is located on the front PCB.
Voltage sense is recommended. Connect 0.75
mm² wires to +V-sense and –V-sense and use a 5
AT fuse near the battery for protection. The
connector is located on the front PCB.
Connect the starter battery (if present) to the
Trickle-charge connector located near the minus-
output bolt. Use a 25 AT carfuse near the battery
for protection.
If used, the Phoenix Charger Control panel can
be connected by means of a standard 8-pole
communication cable with 8-pole communication
connector. The maximum length is 100 m.
Connect battery cables to the charger. Note that
there’s only one “minus”- output to connect both
battery minus poles. Use a fuse according the
table near the battery for protection.
Connect battery cables to the battery.
Watch if the POLARITY LED does NOT
illuminate.
If it does reverse battery cables
Put the car fuses in their sockets
Connect the AC-in by means of a 3-core cable of
2.5 – 4 mm² flexible core to the AC-in terminal
block. Note that a real PE-connection is strictly
necessary.
Replace the frontplate.
Phoenix Charger dimensions
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix acculader 12 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix acculader 12 30 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 1.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info