785439
75
Zoom out
Zoom in
Previous page
1/102
Next page
9
EN NL FR DE ES SE Appendix
4.3 Fusible de seguridad CC
Dentro del inversor no hay fusible de seguridad; este deberá instalarse en el exterior. Los
fusibles de seguridad recomendados pueden verse a continuación:
12/1600
24/1600
48/1600
12/2000
24/2000
48/2000
Fusible CC
recomendado
250 A 125 A 60 A 300 A 150 A 80 A
12/3000
24/3000
48/3000
Fusible CC
recomendado
400 A 250 A 125 A
4.4 Conexión del cableado CA
Este producto es un dispositivo de clase de seguridad I (suministrado con
terminal de puesta a tierra).
El cable neutro de la salida CA de este inversor está conectado al
chasis (ver apéndice B para 1600VA/2000VA y apéndice C para 3000VA).
Con esto se garantiza el funcionamiento correcto del GFCI (o RCCB) que
deberá instalarse en la salida AC del inversor.
El chasis de este producto debe conectarse a tierra, al chasis (de un
vehículo) o a una placa de toma de tierra o al casco (de un barco).
Procedimiento
Los terminales están claramente indicados. De izquierda a derecha: “L” (fase), “N” (neutro) y
"PE" (tierra).
4.5 Opciones de conexión
Existen varias opciones de conexión distintas:
4.5.1 Panel de control remoto y conmutador on/off remoto
El producto puede manejarse de forma remota de tres maneras:
- Con un smartphone (iOS o Android) y la app VictronConnect.
- Con un interruptor externo (conectado al conector remoto bifásico). Sólo funciona si el
conmutador del inversor está en “on”.
- Con el panel de control del inversor Phoenix (conectado al conector remoto bifásico, ver
apéndice A). Sólo funciona si el conmutador del inversor está en “on”.
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Phoenix 12 3000 Omvormer at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Phoenix 12 3000 Omvormer in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info