3.3.3 Activating equalisation or forced absorption
The MultiPlus can be put into both these states from the remote panel as well as with the front
panel switch, provided that all switches (front, remote and panel) are set to “on” and no
switches are set to “charger only”.
In order to put the MultiPlus in this state, the procedure below should be followed.
If the switch is not in the required position after following this procedure, it can be switched
over quickly once. This will not change the charging state.
NOTE: Switching from “on” to “charger only” and vice versa, as described below, must be done quickly. The
switch must be toggled such that the intermediate position is 'skipped', as it were. If the switch remains in
the “off” position even for a short time, the device may be turned off. In that case, the procedure must be
restarted at step 1. A certain degree of familiarisation is required when using the front switch on the
Compact in particular. When using the remote panel, this is less critical.
Procedure:
1. Check whether all switches (i.e. front switch, remote switch or remote panel switch if present) are in the
“on” position.
2. Activating equalisation or forced absorption is only meaningful if the normal charging cycle is completed
(charger is in 'Float').
3. To activate:
a. Switch rapidly from “on” to “charger only” and leave the switch in this position for ½ to 2 seconds.
b. Switch rapidly back from “charger only” to “on” and leave the switch in this position for ½ to 2 seconds.
c. Switch once more rapidly from “on” to “charger only” and leave the switch in this position.
4. On the MultiPlus the three LEDs “Inverter”, “Charger” and “Alarmwill now flash 5 times.
If a MultiControl panel is connected, on the panel the LEDs “bulk”, “absorption” and “float” will also flash 5
times.
5. Subsequently, on the MultiPlus the LEDs “Bulk”, “Absorption” and “Float” will each light during 2
seconds.
If a MultiControl panel is connected, on the panel the LEDsBulk”, “Absorption” and “Float” will also each
light during 2 seconds.
6.
a. If the switch on the MultiPlus is set to “on” while the “Bulk” LED lights, the charger will switch to
equalisation.
Similarly, if the switch on the MultiControl panel is set to “on” while the “Bulk” LED lights, the charger will
switch to equalisation.
b. If the switch on the MultiPlus is set to “on” while the “Absorption” LED lights, the charger will switch to
forced absorption.
Similarly, if the switch on the MultiControl panel is set to “on” while the “Absorption” LED lights, the charger
will switch to forced absorption.
c. If the switch on the MultiPlus is set to “on” after the three LED sequence has finished, the charger will
switch to “Float”.
Similarly, if the switch on the MultiControl panel is set to “on” after the three LED sequence has finished,
the charger will switch to “float”.
d. If the switch has not been moved, the MultiPlus will remain in ‘charger only’ mode and switch to “Float”.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron MultiPlus C 24 1200 25-16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron MultiPlus C 24 1200 25-16 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1.61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info