APPENDIX A: Overview connections
ANNEXE A : Vue d’ensemble des connections
APÉNDICE A: Conexiones generales
APPENDIX A: Översikt kontakter
EN:
NL:
A
AC input M6 AC IN-1 Left to right: L (phase), N (neutral).
B
2x RJ45 connector for remote panel and/or parallel and 3-phase operation.
C
AC output M6 AC OUT-1. Left to right: L (phase), N (neutral).
D
AC output M6 AC OUT-2. Left to right: N (neutral), L (phase).
E
Terminals for: (left to right)
Voltage sense
Temperature sensor
Aux input 1
Aux input 2
GND-relay
Starter battery plus + (starter battery minus must be connected to service battery minus)
Programmable relay contacts K1
Programmable relay contacts K2
F
Double M8 battery minus connection.
G
Double M8 battery positive connection.
H
Connector for remote switch:
Short left and middle terminal to switch “on”.
Short right and middle terminal to switch to “charger only”.
I
Alarm contact: Left to right: NC, NO, COM.
K
Push buttons for set-up mode
L
Primary ground connection M8 (PE).
M
DIP switches for set-up mode.
N
Slide switches, factory setting SW1= off position, SW2 = off position.
SW1: Off = internal GND relay selected, On = external GND relay selected (to connect ext GND relay: see E).
SW2: No application. To be used for future features.
P
AC IN-1, AC OUT-1 and AC OUT-2 M6 earth connection (ground).
A
Wisselspanning ingang M6 AC IN-1. Van links naar rechts: L (fase), N (nul).
B
2x RJ45 connector voor afstandsbedieningspaneel en/of parallel and 3-fase bedrijf.
C
Wisselspanning uitgang M6 AC OUT-1. Van links naar rechts: L (fase), N (nul).
D
Wisselspanning uitgang M6 AC OUT-2. Van links naar rechts: N (nul),L (fase).
E
Aansluitklemmen voor: (van links naar rechts)
Voltage sense
Temperature sensor
Aux ingang 1
Aux ingang 2
GND-relais
Start accu plus + (de min van start accu moet vebonden zijn met de min van de service accu)
Relais contacten K1
Relais contacten K2
F
Dubbele M8 accu min aansluiting.
G
Dubbele M8 accu plus aansluiting.
H
Aansluitklemmen voor afstandbedieningsschakelaar.
Verbind de linker klem en de middelste klem om de Quattro aan te schakelen.
Verbind de rechter klem en de middelste klem voor ‘alleen laden’.
I
Alarm contact: Van links naar rechts: NC, NO, COM.
K
Drukknoppen om de instellingen in het micropressor geheugen op te slaan.
L
Primaire aarde M8.
M
Instel DIP switches.
N
Schuifschakelaars, fabrieksinstelling: SW1= onderste stand (uit), SW2 = onderste stand (uit)
SW1: Uit = intern GND-relais geselecteerd, Aan = extern GND-relais geselecteeerd (extern aardrelais aan te sluiten
via klemmen, zie E).
SW2: Niet in gebruik. Toepasbaar in de toekomst.
P
Aarde aansluiting M6 voor zowel AC IN-1, AC OUT-1 en AC OUT-2.
150


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron MultiPlus 24 5000 120-100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron MultiPlus 24 5000 120-100 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 2.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info