2. DESCRIPTION
2.1 General
Multifunctional
The Multi gets its name from the multiple functions it can perform. It is a powerful true sine
wave inverter, a sophisticated battery charger that features adaptive charge technology and a
high-speed AC transfer switch in a single enclosure. Beside these primary functions, however,
the Multi has several advanced features that provide a range of new applications as outlined
below.
Uninterrupted AC power
In the event of a grid failure, or shore or generator power being disconnected, the inverter
within the Multi is automatically activated and takes over supply to the connected loads. This
happens so fast (less than 20 milliseconds) that computers and other electronic equipment
will continue to operate without disruption.
Parallel and 3-phase operation capability (800VA and 1200VA models only)
Up to 6 inverters can operate in parallel to achieve higher power output.
Operation in 3-phase configuration is also possible.
PowerControl Dealing with limited generator or shore side power
With a Multi Control Panel a maximum generator or shore current can be set. The Multi will
then take account of other AC loads and use whatever is extra for charging, thus preventing
the generator or shore supply from being overloaded.
PowerAssist Boosting the capacity of shore or generator power (800VA and 1200VA
models only)
This feature takes the principle of PowerControl to a further dimension allowing the MultiPlus
Compact to supplement the capacity of the alternative source. Where peak power is so often
required only for a limited period, it is possible to reduce the size of generator needed or
conversely enable more to be achieved from the typically limited shore connection. When the
load reduces, the spare power is used to recharge the battery.
Programmable relay
The Multi is equipped with a programmable relay that by default is set as an alarm relay. The
relay can be programmed for all kinds of other applications however, for example as a starter
relay for a generator.
2.2 Battery charger
Adaptive 4-stage charging characteristics: bulk absorption float storage
The microprocessor-driven adaptive battery management system can be adjusted for various
types of batteries. The adaptive function automatically adapts the charging process to battery
use.
The right amount of charge: variable absorption time
In the event of slight battery discharge, absorption is kept short to prevent overcharging and
excessive gas formation. After deep discharging, the absorption time is automatically
extended in order to fully charge the battery.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron MultiPlus 24 1200 25-16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron MultiPlus 24 1200 25-16 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1.58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info