8. TECHNICAL DATA
12 Volt
24 Volt
48 Volt
MultiPlus 12/500/20
MultiPlus 24/500/10
MultiPlus 48/500/6
MultiPlus 12/800/35
MultiPlus 24/800/16
MultiPlus 48/800/9
MultiPlus 12/1200/50
MultiPlus 24/1200/25
MultiPlus 48/1200/13
PowerControl / PowerAssist Yes / No Yes / Yes
Transfer switch 16A
INVERTER
Input voltage range 9,5 17V 19 33V 3866V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3)
500VA
800VA
1200VA
Cont. output power at 25°C
430W
700W
1000W
Cont. output power at 40°C 400W 650W
900W
Cont. output power at 65°C
300W
400W
600W
Peak power 900W 1600W 2400W
Maximum efficiency 90 / 91 / 92% 92 / 93 / 94%
93 / 94/95%
Zero-load power 6 / 6 / 7W 7 / 7 / 8W
10 / 9 / 10W
Zero-load power in search mode
2 / 2 / 3W
2 / 2 / 3W
3 / 3 /3W
CHARGER
AC Input Input voltage range: 187-265 VAC Input frequency: 45 65 Hz
Charge voltage 'absorption'
14,4 / 28,8 / 57,6V
Charge voltage 'float' 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4)
20 / 10 / 6A
35 / 16 / 9A
50 / 25 / 13A
Charge current starter battery
1 A (12V and 24V models only)
Battery temperature sensor
Yes
GENERAL
Programmable relay (5)
Yes
Protection (2) a – g
Common Characteristics
Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection
16 / 10 / 10 mm²
25 / 16 / 10 mm²
35 / 25 / 10 mm²
230V AC-connection G-ST18i connector
Weight 4,4 kg 6,4 kg 8,2kg
Dimensions (h x w x d)
311 x 182 x 100 mm
360 x 240 x 100 mm
406 x 250 x 100 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity
EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-4
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non-linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for:
general alarm, DC under voltage or generator start/stop signal function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDC
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron MultiPlus 12 500 20-16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron MultiPlus 12 500 20-16 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1.58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info