8. Technical Data
MultiPlus 12/2000/80
MultiPlus 24/2000/50
MultiPlus 48/2000/25
PowerControl / PowerAssist Yes
Transfer switch 32A
INVERTER
Input voltage range 9,5 – 17V 19 – 33V 38– 66V
Output Output voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)
Cont. output power at 25°C (3) 2000VA
Cont. output power at 25°C 1600W
Cont. output power at 40°C 1400W
Cont. output power at 65°C 1000W
Peak power 3500W
Maximum efficiency in % 93 / 94 / 95
Zero-load power 10 / 11 / 11W
Zero-load power search mode 3 / 4 / 4W
CHARGER
AC Input Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz
Charge voltage 'absorption' 14,4 / 28,8 / 57,6V
Charge voltage 'float' 13,8 / 27,6 / 55,2V
Storage mode 13,2 / 26,4 /52,8V
Charge current house battery (4) 80 / 50 / 25A
Charge current starter battery 1 A (12V and 24V models only)
Battery temperature sensor Yes
GENERAL
Programmable relay (5) Yes
Protection (2) a – g
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE
Common Characteristics Material & Colour: Steel/ABS (blue RAL 5012) Protection category: IP 21
Battery-connection M8 bolts
230V AC-connection Screw terminals 13 mm² (6 AWG)
Weight 15,2kg
Dimensions (h x w x d) 506 x 234 x 146 mm
STANDARDS
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
Emission / Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles ECE R10-4
MultiPlus 2kVA 230V
Page 17 Technical Data
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron MultiPlus 12 2000 80-32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron MultiPlus 12 2000 80-32 in the language / languages: English as an attachment in your email.

The manual is 1.31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info