785222
30
Zoom out
Zoom in
Previous page
1/40
Next page
9.4. Tail current
The battery is considered as “fully charged” once the charge current has dropped to less than the set “Tail current” parameter.
The “Tail current” parameter is expressed as a percentage of the battery capacity.
Remark: Some battery chargers stop charging when the current drops below a set threshold. In these cases, the tail current must
be set higher than this threshold.
As soon as the battery monitor detects that the voltage of the battery has reached the set “Charged voltage” parameter and the
current has dropped below the “Tail current” for a certain amount of time, the battery monitor will set the state of charge to 100%.
Default setting Range Step size
4.00% 0.50 - 10.00% 0.1%
9.5. Charged detection time
This is the time the “Charged voltage” and “Tail current” must be met in order to consider the battery fully charged.
Default setting Range Step size
3 minutes 0 - 100 minutes 1 minute
9.6. Peukert exponent
The Peukert exponent for Lithium Smart batteries is 1.05. This is a fixed setting and cannot be changed.
9.7. Charge efficiency factor
The “Charge Efficiency Factor” compensates for the capacity (Ah) losses during charging. A setting of 100% means that there are
no losses.
A charge efficiency of 95% means that 10Ah must be transferred to the battery to get 9.5Ah actually stored in the battery. The
charge efficiency of a battery depends on battery type, age and usage. The battery monitor takes this phenomenon into account
with the charge efficiency factor.
The charge efficiency factor for Lithium Smart batteries is 99% This is a fixed setting and cannot be changed.
9.8. Current threshold
When the current measured falls below the “Current threshold” value it will be considered zero. The “Current threshold” is used to
cancel out very small currents that can negatively affect the long-term state of charge readout in noisy environments. For
example, if the actual long-term current is 0.0A and, due to injected noise or small offsets, the battery monitor measures 0.05A
the batery monitor might, in the long term, incorrectly indicate that the battery is empty or will need to be recharged. When the
current threshold in this example is set to 0.1A, the battery monitor calculates with 0.0A so that errors are eliminated.
The current threshold is fixed at 0.1A
9.9. Discharge floor
The “Discharge floor” parameter is used in the time remaining calculation. The battery monitor calculates the time it takes until the
set “discharge floor” has been reached. It is also used to set the state of charge alarm defaults.
The discharge floor parameter is fixed at 15%.
9.10. SoC cycle end
The state of charge cycle end setting is used to ......
This setting is fixed at 90%.
9.11. SoC cycle
The state of charge cycle setting is used to ......
This setting is fixed at 65%.
9.12. SoC full discharge
The state of charge full discharge setting is used to ......
Lynx Smart BMS
Page 27 Battery monitor settings
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Lynx Smart BMS 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Lynx Smart BMS 500 in the language / languages: English as an attachment in your email.

The manual is 3.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info