6. TECHNICAL SPECIFICATIONS
48/6000
Parallel and 3-phase operation
no
Maximum PV input power
4000W
Maximum DC charging power
4000W
INVERTER
DC Input voltage range
38 64V
Output
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
Continuous output power at 25°C
Increases linearly from 4800W at 46 VDC to 5300W at 52 VDC
Continuous output power at 40°C
4500W
Continuous output power at 65°C
3300W
Peak power
9kW for 3 seconds
Short-circuit output current
50A
Maximum efficiency
96.5% at 1 kW load
94% at 5 kW load
Zero load power
20W
Low battery shutdown
37.2 V (adjustable)
Low battery restart
43.6 V (adjustable)
SOLAR
Maximum DC voltage
450V
Nominal DC voltage
300V
Start-up voltage
120V
MPPT voltage range
80 400V
DC input current limit
Maximum DC input current
18A
20A
Earth leakage trip level
30 mA
Isolation fail level
(detection before start-up)
100 kΩ
CHARGER
Charge voltage 'absorption' (V DC)
57.6V
Charge voltage 'float' (V DC)
55.2V
Maximum charge current
100A
Battery temperature sensor
Yes
Battery voltage sense
Yes
GENERAL
Auxiliary output
No
Programmable relay (3)
Yes
Protection (2)
a - g
VE.Direct port and VE.Can port
Yes
General purpose analog/digital in port
Yes, 2x
Remote on-off
Yes
Operating temperature range
-40 to +65°C (fan assisted cooling)
Humidity (non-condensing)
max 95%
ENCLOSURE
Material & Colour
steel, blue RAL 5012
Protection category
IP22
Battery-connection
PV Connection
Two M8 bolts
2 positive & 2 negative MC4
230 V AC-connection
Screw terminals 13 mm² (6 AWG)
Weight
11 kg
Dimensions (hxwxd)
425 x 440 x 125 mm
STANDARDS
Safety
EN-IEC 60335-1, EN-IEC 60335-2-29,
EN-IEC 62109-1, EN-IEC 62109-2
Emission, Immunity
EN 55014-1, EN 55014-2
EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
1) Can be adjusted to 60 Hz
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 VAC on inverter output
g) Solar earth leakage
3) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function, including minimum closed time and
relay-off delay. DC rating: 4A up to 35VDC and 1A up to 70VDC
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Inverter RS 48 6000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Inverter RS 48 6000 in the language / languages: English, German, Dutch, French, Swedish as an attachment in your email.

The manual is 0.82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info