3.INSTALLATION
3.1 Location of the inverter
Try and keep the distance between the product and the battery to a minimum in order to minimise cable voltage losses
3.2 Connection to the battery
In order to utilize the full capacity of the product, batteries with sufficient capacity and battery cables with sufficient cross section should
be used. See table:
min
unit
400
Ah
100
Ah
150
A
Minimum cross section (mm2) per +
and - connection terminal
0 – 2 m
35
mm2
2 5 m
70
mm2
Use a torque wrench with insulated box spanner in order to avoid
shorting the battery.
Maximum torque: 14 Nm
Avoid shorting the battery cables.
Undo the two screws at the bottom of the enclosure and remove the service panel.
Connect the battery cables.
Tighten the nuts well for minimal contact resistance.
3.3 Wire size for connecting the inverter chassis to ground
The earth conductor from the earth lug on the chassis to ground should have at least half the cross-section of the conductors used for
the battery connection.
For best operating results, the inverter should be placed on a flat surface. To
ensure a trouble free operation of the inverter, it must be used in locations that
meet the following requirements:
a) Avoid any contact with water. Do not expose the inverter to rain or
moisture.
b) Do not place the unit in direct sunlight. Ambient air temperature should
be between -20°C and 40°C (humidity < 95% non-condensing).
c) Do not obstruct the airflow around the inverter. Leave at least 30
centimeters clearance above and below the inverter.
When the inverter is running too hot, it will shut down. When the inverter has
reached a safe temperature level the unit will automatically restart again.
This product contains potentially dangerous voltages. It should only be installed
under the supervision of a suitable qualified installer with the appropriate training,
and subject to local requirements. Please contact Victron Energy for further
information or necessary training.
Excessively high ambient temperature will result in the following:
Reduced service life.
Reduced charging current.
Reduced peak capacity, or shutdown of the inverter.
Never position the appliance directly above lead-acid batteries.
The Inverter RS is suitable for wall mounting. For mounting purposes, a hook and
two holes are provided at the back of the casing. The device must be fitted
vertically for optimal cooling.
For safety purposes, this product should be installed in a heat-resistant
environment. You should prevent the presence of e.g. chemicals, synthetic
components, curtains or other textiles, etc., in the immediate vicinity.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Inverter RS 48 6000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Inverter RS 48 6000 in the language / languages: English, German, Dutch, French, Swedish as an attachment in your email.

The manual is 0.82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info