DE:
A
Lastanschluss AC-OUT-1 Von links nach rechts: N (neutral), PE (Erde/Masse), L (Phase)
B
Lastanschluss AC-OUT-2 Links nach rechts: N (neutral), PE (Erde/Masse), L (Phase)
C
AC-Eingang. AC-IN Links nach rechts: N (neutral), PE (Erde/Masse), L (Phase)
D
Alarmkontakt: von links nach rechts NO, NC, COM.
E
Ohne Assistenten starten: Halten Sie diese Taste beim Start gedrückt.
F
Primärer Erdungsanschluss M6 (PE)
G
M8 Plusanschluss der Batterie
H
M8 Minusanschluss der Batterie
I
Schalter: -:Ein, 0:Aus, =:nur Ladegerät
J
Klemmen von oben nach unten:
1. 12 V 100 mA
2. Programmierbarer Kontakt K1 offener Kollektor 70 V 100 mA
3. Externes Erdungsrelais +
4. Externes Erdungsrelais -
5. Aux Input 1 +
6. Aux Input 1
7. Aux Input 2 +
8. Aux Input 2
9. Temperatursensor +
10. Temperatursensor
11. Batteriespannungssensor +
12. Batteriespannungssensor -
K
Externer Stromsensor
L
2x RJ45-VE-BUS-Stecker für die Fernsteuerung und/oder Parallel- / 3-Phasenbetrieb.
M
Stecker für Fernbedienungsschalter: Kurzschluss auslösen zum "Ein-"schalten
N
Dedizierter BMS-Can-Port (VE.Can nicht unterstützt)
O
USB
P
Rückstellknopf: Wofür wird der Rückstellknopf verwendet? MCO
Q
Ethernet-Anschluss
R
VE.Direct Anschluss
S
Solar Plus M6 Schraube
T
Solar Minus M6 Schraube
ES:
A
Conexión de la carga. AC-OUT-1 De izquierda a derecha: N (neutro), PE (tierra/masa), L (fase)|
B
Conexión de la carga. AC-OUT-2 De izquierda a derecha: N (neutro), PE (tierra), L (fase)
C
Entrada de CA. AC-IN De izquierda a derecha: N (neutro), PE (tierra), L (fase)
D
Contacto de la alarma: de izquierda a derecha NO, NC, COM.|
E
Inicio sin Asistentes: Mantenga pulsado este botón al iniciar
F
Conexión a tierra primaria M6 (PE)
G
Conexión positivo batería M8.
H
Conexión negativo batería M8.
I
Conmutador: -:On, 0:Off, =:cargador solamente
J
Terminales de arriba a abajo:
1. 12 V 100 mA
2. Contacto programable K1 colector abierto 70 V 100 mA
3. Relé de puesta a tierra externo +
4. Relé de puesta a tierra externo -
5. Entrada aux 1 +
6. Entrada aux 1 -
7. Entrada aux 2 +
8. Entrada aux 2 -
9. Sensor de temperatura +
10. Sensor de temperatura -
11. Sensor de tensión de la batería +
12. Sensor de tensión de la batería -
K
Sensor de corriente externo
L
2 conectores VE-BUS RJ45 para panel remoto y/o funcionamiento en paralelo o trifásico
M
Conector para conmutador remoto: Puentear para activar.
N
Puerto BMS-Can exclusivo (VE.Can no compatible)
O
USB
P
Botón de reinicio: ¿Para qué se utiliza el botón de reinicio? MCO
Q
Puerto Ethernet
R
Puerto VE.Direct
S
Perno solar positivo M6
T
Perno solar negativo M6
137


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 2.84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info