EN NL FR DE ES IT Appendix
5.5.2. DIP switch 3 tot 7
Met deze DIP switches kunnen de volgende instellingen gedaan worden:
- Acculaadspanning en absorptietijd
- Frequentie omvormer
- Zoekmodus
- AC-ingangsstroomlimiet 12A of 6A
ds3-ds4: Laadspanningsinstelling
ds3-ds4 Absorptie-
spanning
Druppel-
ladings-
spanning
Opslag-
spanning
Absorptie-
tijd (uren) Geschikt voor
ds3=off
ds4=off
(fabrieksinstelling)
14,4
28,8
57,6
13,8
27,6
55,2
13,2
26,4
52,8
8
Gel Victron
Deep
Discharge
Gel Exide A200
AGM Victron
Deep
Discharge
ds3=on
ds4=off
14,1
28,2
56,4
13,8
27,6
55,2
13,2
26,4
52,8
8
Gel Victron
Long Life
(OPzV)
Gel Exide A600
(OPzV)
Gel MK battery
ds3=off
ds4=on
14,7
29,4
58,8
13,8
27,6
55,2
13,2
26,4
52,8
5
AGM Victron
Deep
Discharge
Buisjesplaat of
OPzS-accu’s in
semi-
druppelmodus
AGM spiraalcel
ds3=on
ds4=on
15,0
30,0
60,0
13,8
27,6
55,2
13,2
26,4
52,8
6
Buisjesplaat
tractie-accu’s of
OPzS-accu’s in
cyclische
modus
Accu's met een hoog antimoon gehalte kunnen over het algemeen geladen worden met een
lagere absorptiespanning dan accu's met een laag antimoon gehalte. (Zie het boek
Elektriciteit aan boordop www.victronenergy.com). Vraag bij gebruik van andere typen
accu’s aan uw acculeverancier de juiste laadspanningen en laat zonodig de MultiPlus
Compact hierop (met behulp van VEConfigure) aanpassen.
De laadstroom staat ingesteld op 75% van nominale laadstroom. Vaak is dit een te hoge
laadstroom.
De meeste accu’s dienen geladen te worden met een stroom van 0,1 tot 0,2 keer de
accucapaciteit.
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron EasySolar 24 1600 40 MPPT 100 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron EasySolar 24 1600 40 MPPT 100 50 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info