4. Spezifikationen
Centaur
Ladegerät
12/20
12/30
24/16 12/40
12/50
12/60
24/30 12/80
24/40 12/100
24/60
Gemeinsame
Merkmale
Eingangsspannung: 90 265V Eingangsfrequenz: 45 65Hz Leistungsfaktor: 1
Ladespannung
Absorption
(V DC)
14,3 / 28,5 (1)
Ladespannung
Float
(V DC)
13,5 / 27,0 (1)
Leistungsausgänge
3
Ladestrom (A) (2)
20 30 /16 40 50 60/30 80/40 100/60
Amp.-Anzeige
Ausgangsleistung
Ja
Ladekennlinie
IUoU (Dreistufen Charakteristik)
Empfohlene
Batteriekapazität (Ah)
80 - 200 120 300
45 - 150 160 - 400 200 - 500 240 600
120 - 300 320 800
160 - 400 400 1000
240 - 600
Temperatur Sensor
Zwangskühlung
Ja, Temperatur- und Strom- geregelter Lüfter
Schutz
Ausgangskurzschluß, Übertemperatur
Betriebs-
Temperaturbereich
-20 to 60°C (0 - 140°F)
Brandschutz
Ja
Rel. Luftfeuchte
max 95%
Gehäuse
Material & Farbe
Aluminium (blau RAL 5012)
Ba
tterie-Anschlüsse M6 Bolzen M6 Bolzen M8 Bolzen M8 Bolzen M8 Bolzen M8 Bolzen M8 Bolzen
Wechselstrom-
Anschluß
Schraubklemme 4mm² (AWG 6)
Schutzklasse
IP 20
Gewicht kg (lbs)
3,8 (8.4) 3,8 (8.4) 5 (11) 5 (11) 5 (11) 12 (26) 12 (26)
Abmessungen hxwxd
in
mm
(hxwxd in Zoll)
355x215x110
(14.0x8.5x4.3) 355x215x110
(14.0x8.5x4.3) 426x239x135
(16.8x9.4x5.3) 426x239x135
(16.8x9.4x5.3) 505x255x130
(19.9x10.0x5.2) 505x255x130
(19.9x10.0x5.2) 505x255x230
(19.9x10.0x9.1)
Normen
Sicherheit
EN 60335-2-29, UL 1236
Emission
EN 55014, EN 61000-3-2, EN 61000 3-3
EMV
EN 55014-2
1) Standard Einstellung. Optimale charge/float Spannungen für Nasse Blei-Säure, Gel- oder AGM
Batterien einstellbar mit Tip-Schalter.
2) Bis zu 40°C (100°F) Umgebungstemperatur. Leistung sinkt auf 80% des Nennwerts bei 50°C (120°F)
und auf 60% bei 60°C (140°F).
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Centaur acculader 12 20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Centaur acculader 12 20 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info