5
EN NL FR DE ES SE
5. Protection
Load Overload
If the load current exceeds the rated current of controller (≥1.05 times
rated discharge current), the controller will disconnect the load.
Overloading must be cleared, then press the switch button.
Load Short Circuit
Fully protected against load wiring short-circuit (≥2 times rated
discharge current). After one automatic load reconnect attempt, the
fault must be cleared by restarting the controller or pressing the switch
button.
PV Reverse Polarity
Full protection against PV reverse polarity, no damage to the
controller will result. Correct the wiring to resume normal operation.
Battery Reverse Polarity
Full protection against battery reverse polarity, no damage to the
controller will result. Correct the wiring to resume normal operation.
Damaged Temperature Sensor
If the temperature sensor short-circuited or damaged, the controller will
be charging or discharging at the default temperature (25°C).
Overheating Protection
If the temperature of the controller heat sink exceeds 85°C, the controller
will stop charging and discharging. When the temperature is below 75°C,
the controller will restart.
High Voltage Transients
Limited internal transient protection.
In lightning prone areas, additional external suppression is
recommended.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar PWM Pro 12 24V-30A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar PWM Pro 12 24V-30A in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info