785262
8
Zoom out
Zoom in
Previous page
1/67
Next page
6
Main display. It shows battery voltage, battery capacity,
charging and discharging status.
Press MENU to enter next display.
display. press on the
MENU key for
several seconds until
the numbers flash, you
are in:
Battery type setting.
See table below.
The factory setting is b01
*The controllers do not have a remote on/off input. Therefore use LiFePO4 batteries with integrated BMS
only (such as the Victron SuperPack batteries)
NA for 48V
key again and you are
in:
Low voltage disconnect
The factory setting is 11.2V
[22.4V] 44.8V
key again and you are
in:
Low voltage reconnect
The factory setting is 12.6V
[25.2V] 50.4V
Solar Voltage display. It shows Solar Panel voltage,
battery capacity status.
Press MENU to enter next display.
Battery type
Battery
voltage
Absorbti
on
voltage
Float
voltage
Low voltage
disconnect
factory
setting
Low voltage
disconnect
range
Low voltage
reconnect
factory setting
Low voltage
reconnect range
b01
LEAD-ACID
[AGM]
12.0V [24V]
48V
14.4V
[28.8V]
57.6V
13.7V
[27.4V]
54.8V
11.2V [22.4V]
44.8V
10.5V-12.0V
in steps of
0.1V
12.6V [25.2V]
50.4V
12.0V-13.5V in
steps of 0.1V
b02
LEAD-ACID
[Gel]
12.0V [24V]
48V
14.2V
[28.4V]
56.8V
13.7V
[27.4V]
54.8V
11.2V [22.4V]
44.8V
10.5V-12.0V
in steps of
0.1V
12.6V [25.2V]
50.4V
12.0V-13.5V in
steps of 0.1V
b03
LEAD-ACID
[Wet]
12.0V [24V]
48V
14.6V
[29.2V]
58.4V
13.7V
[27.4V]
54.8V
11.2V [22.4V]
44.8V
10.5V-12.0V
in steps of
0.1V
12.6V [25.2V]
50.4V
12.0V-13.5V in
steps of 0.1V
b04*
12V
LiFePO4
12.8V
14.2V
13.35V
11.2V
10.5V-12.0V
in steps of
0.1V
12.6V
12.0V-13.5V in
steps of 0.1V
b05*
24V
LiFePO4
25.6V
28.4V
26.7V
22.4V
21.0V-24.0V
in steps of
0.1V
25.2V
24.0V-27.0V in
steps of 0.1V
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar PWM 48V-10A LCD USB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar PWM 48V-10A LCD USB in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 1.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info