5. Alarms
High temperature
Temp <85, controller works normally.
When temp ≥ 85, controller will adopt first protection
phase:
1. Controller will lower the PV input current, in
order to lower the controller temp; but Load
works normally. There is no alarm on LCD
display.
When temp is >90, controller will adopt second
protection phase:
2. Controller will cut off PV input current. Load
output cut off. A high temp alarm icon will
show on LCD to notice user.
When temp down under 82, the controller will again turn
on PV input and Load output. Alarm icon disappears.
Low voltage.
Empty battery symbol flashing means the battery is
discharged lower than the LVD voltage. The charge
Controller has disabled the output. User should charge the
battery until it is up to LVR Low voltage re-connect voltage
and then BlueSolar Charge Controller will recover the
output status.
Short-circuit protection.
This display means a short-circuit protection occurs. The
controller will switch off the output and wait for 30s and
then try to recover again. User should check and remove
the trouble in time.
Over-current protection.
This display means an output over-current occurs. The
controller will switch off the output and wait for 30s and
then try to recover again. User should check and remove
the trouble in time.
Shut down after 60s in case of 110%-130% load.
Shut down after 5s in case of 130%-160% load.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar PWM 12 24V-30A LCD USB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar PWM 12 24V-30A LCD USB in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 1.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info