785382
75
Zoom out
Zoom in
Previous page
1/103
Next page
9
EN NL FR DE ES SE Appendix
3.5. Configuración del controlador
Algoritmo de carga totalmente programable (consulte la sección
Asistencia y Descargas > Software en nuestra página web), y
ocho algoritmos preprogramados, seleccionables mediante
interruptor giratorio:
Pos
Tipo de batería sugerido
Absorción
V Flotación
V
Ecua.
V
a %Inom
dV/dT
mV/°C
0
Gel Victron Long Life (OPzV)
Gel Exide A600 (OPzV)
Gel MK
28,2 27,6
31,8
al 8 % -32
1
Gel Victron Deep Discharge
Gel Exide A200
AGM Victron Deep
Discharge
Placa tubular estacionaria
(OPzS)
Rolls Marine (inundada)
Rolls Solar (inundada)
28,6 27,6 32,2
al 8 % -32
2
Valores predeterminados
Gel Victron Deep Discharge
Gel Exide A200
AGM Victron Deep
Discharge
Placa tubular estacionaria
(OPzS)
Rolls Marine (inundada)
Rolls Solar (inundada)
28,8 27,6 32,4
al 8 % -32
3
AGM Placa en espiral
Placa tubular estacionaria
(OPzS)
Rolls AGM
29,4 27,6
33,0
al 8 % -32
4
Baterías de tracción de
placa tubular PzS o
Baterías OPzS
29,8 27,6 33,4
al 25 % -32
5
Baterías de tracción de
placa tubular PzS o
Baterías OPzS
30,2 27,6
33,8
al 25 % -32
6
Baterías de tracción de
placa tubular PzS o
Baterías OPzS
30,6 27,6
34,2
al 25 % -32
7
Baterías de fosfato hierro y
litio (LiFePo4)
28,4 27,0 n.d. 0
Nota 1: dividir por dos todos los valores en el caso de un sistema de 12V y multiplicar por dos en caso de un
sistema de 48V.
Nota 2: ecualización normalmente apagada, ver sección 3.8. para activarla.
Nota 3: cualquier cambio de configuración realizado con el Bluetooth o mediante VE.Direct anulará
la configuración del interruptor giratorio. Al volver a usar el interruptor giratorio, se anularán las
configuraciones hechas con el Bluetooth o con VE.Direct.
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar MPPT 150 45 MC4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar MPPT 150 45 MC4 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info