785382
64
Zoom out
Zoom in
Previous page
1/103
Next page
14
5. Technische Daten
BlueSolar Laderegler
MPPT 150/45
MPPT 150/60
MPPT 150/70
Batteriespannung
12/24/48V Auto Select (36V: manuell)
Maximaler Batteriestrom
45A
60A
70A
Nenn PV-Leistung, 12V 1a,b)
650W
860W
1000W
Nenn PV-Leistung, 24V 1a,b)
1300W
1720W
2000W
Nenn PV-Leistung, 36V 1a,b)
1950W
2580W
3000W
Nenn PV-Leistung, 48V 1a,b)
2600W
3440W
4000W
Max. PV Kurzschlussstrom 2) 50A 50A 50A
Maximale PV-Leerspannung
150V
Spitzenwirkungsgrad
98%
Eigenverbrauch
Weniger als 35mA @ 12V / 20mA @ 48V
„Konstant“-Ladespannung
(absorption)
Standardeinstellungen: 14,4V / 28,8V / 43,2V / 57,6V (regulierbar)
"Ausgleichs-"Ladespannung 3)
Standardeinstellungen: 16,2V / 32,4V / 48,6V / 64,8V (regulierbar)
„Erhaltungs“-Ladespannung
(float)
Standardeinstellungen: 13,8V / 27,6V / 41,4V / 55,2V (regulierbar)
Ladealgorithmus Mehrstufig, adaptiv (acht vorprogrammierte Algorithmen)
Temperaturkompensation
-16mV/°C / -32mV/°C / -48mV/°C / -64mVC
Schutz
Verpolung an Batterie (Sicherung, kein Zugriff durch den Nutzer)
Kurzschluss Ausgang / Überhitzung
Betriebstemperatur
-30 °C bis +60°C (voller Nennausgang bis zu 40°C)
Feuchte
95% nicht kondensierend
Maximale Höhe
5000 m (voller Nennausgang bis zu 2000 m)
Umgebungsbedingungen
Für Innen Typ 1, keine Bedingungen
Verschmutzungsgrad
PD3
Anschluss für Datenaustausch
und ferngesteuertes Ein-
/Ausschalten
VE.Direct
Siehe Informationsbroschüre zu Datenkommunikation auf unserer
Webseite.
Parallelbetrieb
Ja, jedoch nicht synchronisiert
GEHÄUSE
Farbe Blau (RAL 5012)
PV-Anschlüsse 3)
35mm² / AWG2 (Tr-Modelle), oder duale MC4 Stecker (MC4-
Modelle)
Batterieanschlüsse
35mm² / AWG2
Schutzklasse
IP43 (elektronische Bauteile)
IP 22 (Anschlussbereich)
Gewicht
3kg
Maße (HxBxT)
Tr-Modelle: 185 x 250 x 95mm
MC4-Modelle: 215 x 250 x 95mm
NORMEN
Sicherheit
EN/IEC 62109-1 / UL 1741 / CSA C22.2 NO.107.1-16
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher sort circuit current may damage the controller in case of reverse
polarity connection of the PV array.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar MPPT 150 45 MC4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar MPPT 150 45 MC4 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info