785382
32
Zoom out
Zoom in
Previous page
1/103
Next page
14
5. Specificaties
BlueSolar-laadcontroller MPPT 150/45 MPPT 150/60 MPPT 150/70
Accuspanning
12/24/48V Auto Select (36V: handmatig)
Maximale accustroom
45A
60A
70A
Nominaal PV-vermogen, 12V 1a,b)
650W
860W
1000W
Nominaal PV-vermogen, 24V 1a,b)
1300W
1720W
2000W
Nominaal PV-vermogen, 36V 1a,b)
1950W
2580W
3000W
Nominaal PV-vermogen, 48V 1a,b)
2600W
3440W
4000W
Max. PV kortsluitstroom 2)
50A
50A
50A
Maximale PV-nullastspanning
150V
Piekefficiëntie 98%
Eigen verbruik
Minder dan 35 mA @ 12V / 20mA @ 48V
Laadspanning 'absorptielading'
Standaardinstelling: 14,4V / 28,8V / 43,2V / 57,6V (regelbaar)
Laadspanning 'egalisatie' 3)
Fabrieksinstelling: 16,2V / 32,4V / 48,6V / 64,8V (regelbaar)
Laadspanning 'druppellading'
Standaardinstelling: 13,8V / 27,6V / 41,4V / 55,2V (regelbaar)
Laadalgoritme
Meertraps adaptief (acht voorgeprogrammeerde algoritmes) of
gebruikersgedefinieerd algoritme
Temperatuurcompensatie -16mV/°C / -32mV/°C / -48mV/°C / -64mVC
Beveiliging
Omgekeerde polariteit accu (zekering, niet toegankelijk voor
gebruiker)
Kortsluiting uitgang / Overtemperatuur
Bedrijfstemperatuur
-30 tot +60°C (volledig nominaal vermogen tot 40°C)
Vocht 95%, niet condenserend
Maximale hoogte
5000m (volledig nominaal vermogen tot 2000m)
Omgevingsomstandigheden
Binnen, natuurlijk
Verontreinigingsgraad
PD3
Datacommunicatiepoort en aan/uit
op afstand
VE.Direct
Zie het witboek over datacommunicatie op onze website
Parallelle werking
Ja, maar niet gesynchroniseerd
BEHUIZING
Kleur
Blauw (RAL 5012)
PV-aansluitingen 3)
35mm² / AWG2 (Tr-modellen), of dubbele MC4-stekkers (MC4-
modellen)
Accu-aansluitingen
35mm² / AWG2
Beschermingsklasse
IP43 (elektronische componenten)
IP 22 (aansluitingsgebied)
Gewicht
3kg
Afmetingen (h x b x d)
Tr-modellen: 185 x 250 x 95mm
MC4-modellen: 215 x 250 x 95mm
NORMEN
Veiligheid
NEN-EN/IEC 62109-1 / UL 1741 / CSA C22.2 NO.107.1-16
1a) Als er meer PV-vermogen wordt aangesloten, beperkt de controller het ingangsvermogen.
1b) De controller start pas als de PV-spanning Vaccu + 5V overschrijdt.
Daarna bedraagt de minimale PV-spanning Vaccu + 1V.
2) Een hogere kortsluitstroom kan de controller beschadigen bij omgekeerde
polariteitsaansluiting van het zonnepaneel.
3) MC4-modellen: er zijn eventueel meerdere splitterparen nodig om de aders van de zonnepanelen
parallel te laten lopen
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar MPPT 150 45 MC4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar MPPT 150 45 MC4 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info