5. Specificaties
BlueSolar-laadcontroller MPPT 100/30 MPPT 100/50
Accuspanning 12/24V Auto Select
Maximale accustroom
30A
50A
Nominaal PV-vermogen, 12V 1a,b) 440W 700W
Nominaal PV-vermogen, 24V 1a,b) 880W 1400W
Maximale PV-nullastspanning
100V
100V
Max. PV kortsluitstroom 2)
35A
60A
Piekefficiëntie
98%
98%
Eigen verbruik
12V: 30 mA 24V: 20 mA
Laadspanning 'absorptielading' Fabrieksinstelling: 14,4V / 28,8V (regelbaar)
Laadspanning 'druppellading' Fabrieksinstelling: 13,8V / 27,6V (regelbaar)
Laadspanning 'egalisatie' Fabrieksinstelling: 16,2V / 28,8V (regelbaar)
Laadalgoritme
meertraps adaptief (acht voorgeprogrammeerde algoritmes)
of gebruikersgedefinieerd algoritme
Temperatuurcompensatie
-16mV / °C resp. -32mV / °C
Beveiliging
Omgekeerde polariteit accu (zekering, niet toegankelijk voor
gebruiker), Kortsluiting uitgang
Overtemperatuur
Bedrijfstemperatuur -30 tot +60°C (volledig nominaal vermogen tot 40°C)
Vocht 95%, niet condenserend
Maximale hoogte
5000 m (volledig nominale uitgangsspanning tot 2000 m)
Omgevingsomstandigheden Binnen type 1, natuurlijk
Verontreinigingsgraad
PD3
Datacommunicatiepoort
VE.Direct
Zie het whitepaper over datacommunicatie op onze website
BEHUIZING
Kleur Blauw (RAL 5012)
Vermogensklemmen 13mm² / AWG6
Beschermingsklasse
IP43 (elektronische componenten)
IP22 (aansluitingsgebied)
Gewicht
1,25kg
Afmetingen (h x b x d) 130 x 186 x 70mm
NORMEN
Veiligheid
NEN-EN/IEC 62109-1 / UL 1741 / CSA C22.2
NO.107.1-16
1a) Als er meer PV-vermogen wordt aangesloten, beperkt de controller het ingangsvermogen.
1b) De controller start pas als de PV-spanning Vaccu + 5V overschrijdt.
Daarna bedraagt de minimale PV-spanning Vaccu + 1V.
2) Een hogere kortsluitstroom kan de controller beschadigen bij omgekeerde
polariteitsaansluiting van het zonnepaneel.
3) Fabrieksinstelling: UIT
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar MPPT 100 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar MPPT 100 30 in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 0.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info