5.3 General installation
Do not use modules of different configurations in the same system. The max. number of module (N) = Vmax system / [Voc(at STC)].
Several modules are connected in series and then in parallel to form a PV array, especially for application with a high operation voltage.
If modules are connected in series, the total voltage is equal to the sum of individual voltages.
For applications requiring high currents, several photovoltaic modules can be connected in parallel; the total current is equal to the sum
of individual currents.
Module is supplied with connectors to use for system electrical connections.
Consult rated local wiring regulations to determine system wire size, type, and temperature.
The cross section area of cable and the capacity of connector must be selected to suit the maximum system short circuit
current(Recommended cross section area of cable is 4mm2 for a single module and rated current of a connector is larger than 10A ),
otherwise the cable and connector will be overheated under large current. Please note that the upper limit temperature of cable is
85oC,and the connector is 105oC.
The junction box has a breather port. The breather port must be mounted facing down and can not be exposed to rain. Therefore, the
junction box must be on the higher side of the module when it is mounted.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron BlueSolar 115Wp poly at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron BlueSolar 115Wp poly in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 1.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info