785337
8
Zoom out
Zoom in
Previous page
1/99
Next page
6
3. Charge algorithms
3.1 Smart charge algorithm with optional reconditioning for
lead-acid batteries
Charge voltages at room temperature:
MODE
ABS
V
FLOAT
V
STORAGE
V
RECONDITION
Max V@% of Inom
NORMAL
14,4
13,8
13,2
16,2@8%, max 1h
HIGH
14,7
13,8
13,2
16,5@8%, max 1h
LI-ION
14,2
13,5
13,5
n. a.
For 24V chargers: multiply all voltage values by 2.
NORMAL (14,4V): recommended for flooded flat plate lead
antimony batteries (starter batteries), flat plate gel and AGM
batteries.
HIGH (14,7V): recommended for flooded lead calcium batteries,
Optima spiral cell batteries and Odyssey batteries.
Eight step charge sequence for lead-acid batteries:
1. CHARGE/TEST
Tests if the battery can accept charge, even if the battery is
fully discharged (zero or nearly zero Volt across the
terminals).
All charge status LEDs will flash in case of reverse polarity
connection, short-circuit or if a 12V charger is connected to
a 24V battery.
The TEST LED will flash as long as a charge pulse does
not increase battery voltage to more than 12,5V resp. 25V.
If the flashing persists during several minutes the battery is
probably damaged (internal short-circuit): disconnect the
charger.
A false rejection may occur if a load is simultaneously
draining a very weak or fully discharged battery during the
test phase: disconnect the load and repeat the test.
The charger can be switched to low current mode (see technical
specifications) by pressing the MODE button during 3 seconds. The
MODE LED will blink when in low current mode.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Blue Smart IP65 Acculader 12 25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Blue Smart IP65 Acculader 12 25 in the language / languages: English, German, Dutch, French, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 0.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info