measured again when the charger is in low current mode during
float or storage. Special settings for a cold or hot environment are
therefore not needed.
2.7 Adaptive Battery Management
Lead-acid batteries should be charged in three stages, which are
[1] bulk or constant-current charge,
[2] absorption or topping
charge and [3] float charge.
Several hours of absorption charge are needed to fully charge the
battery and prevent early failure to sulfation¹.
The relatively high voltage during absorption does however
accelerate aging due to grid corrosion on the positive plates.
Adaptive Battery Management limits corrosion by reducing
absorption time when possible, that is: when charging a battery
that is already (nearly) fully charged.
2.8 Storage mode: less corrosion of the positive plates
Even the lower float charge voltage that follows the absorption
period will cause grid corrosion. It is therefore essential to reduce
the charge voltage even further when the battery remains
connected to the charger during more than 48 hours.
2.9 Reconditioning
A lead-acid battery that has been insufficiently charged or has
been left discharged during days or weeks will deteriorate due to
sulfation¹. If caught in time, sulfation can sometimes be partially
reversed by charging the battery with low current up to a higher
voltage.
Remarks:
a) Reconditioning should be applied only occasionally to flat plate VRLA
(gel and AGM) batteries because the resulting gassing will dry out the
electrolyte.
b) Cylindrical cell VRLA batteries build more internal pressure before
gassing and will therefore lose less water when subjected to
reconditioning. Some manufacturers of cylindrical cell batteries
therefore recommend the reconditioning setting in case of cyclic
application.
c) Reconditioning can be applied to flooded batteries to “equalise” the
cells and to prevent acid stratification.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Blue Smart IP65 Acculader 12 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Blue Smart IP65 Acculader 12 15 in the language / languages: English, German, Dutch, French, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 0.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info