4. Especificaciones técnicas
Blue Power IP22 Charger
Blue Smart IP22 Charger
12 V 15/20/30 A 24 V 8/12/16 A
Rango de tensión de entrada
180-265 VAC
Output current, normal mode
15 / 20 / 30 A
8 / 12 / 15 A
Output current, NIGHT or LOW
7,5 / 10 / 15 A
4 / 6 / 8 A
Eficiencia
94%
95%
Consumo en espera
0,5 W
Tensión mínima de la batería Empieza a cargar desde los 0 V (“Batería agotada”)
Tensión de carga de "absorción"
Normal: 14,4 V
Alta: 14,7 V
Li-Ion 14,2 V
Normal: 28,8 V
Alta: 29,4 V
Li-Ion 28,4 V
Tensión de carga de "flotación"
Normal: 13,8 V
Alta: 13,8 V
Li-Ion 13,5 V
Normal: 27,6 V
Alta: 27,6 V
Li-Ion 27,0 V
Tensión de carga de "almacenamiento"
Normal: 13,2 V
Alta: 13,2 V
Li-Ion 13,5 V
Normal: 26,4 V
Alta: 26,4 V
Li-Ion 27,0 V
Capacidad mín. de la batería, modo normal 30/40/60Ah 16/24/32Ah
Capacidad mín. de la batería, noche en baja 15/20/30Ah 8/12/16Ah
Compensación de temp. (sólo baterías de
plomo-ácido)
16 mV/°C 32 mV/°C
Puede utilizarse como fuente de
alimentación
Drenaje de corriente si cargador no
enchufado a red
0,4 Ah/mes 0,6 mA)
Protección
Polaridad inversa Cortocircuito de salida
Sobretemperatura
Cooling
ventilador de bajas rpm (silencioso) (12/15 y 24/08 no
tienen ventilador)
Rango de temp. de funcionamiento -20 a +50°C (potencia completa hasta los 40°C)
Humedad (sin condensación) Máx. 95%
CARCASA
Conexión de la batería
Conector de 13 mm² (AWG6)
Conexión 230 VCA
Cable de 1,5 metros con enchufe CEE 7/7, BS 1363
(RU) o enchufe AS/NZS 3112
Tipo de protección
IP22 (para uso en interiores)
Peso
1,3 kg
Dimensiones (al x an x p)
235 x 108 x 65 mm
ESTÁNDARES
Seguridad
EN 60335-1, EN 60335-2-29
Emisiones
EN 55014-1, EN 61000-6-3, EN 61000-3-2
Inmunidad
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron Blue Smart IP22 Acculader 12 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron Blue Smart IP22 Acculader 12 15 in the language / languages: English, German, Dutch, French, Italian, Swedish, Spanish as an attachment in your email.

The manual is 0.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info