785213
7
Zoom out
Zoom in
Previous page
1/334
Next page
5
NL FR DE ES SE IT PT
EN NL FR DE ES SE IT PT
Setup wizard (alternatively, use the VictronConnect app and smart phone):
1.1 Battery capacity (preferably use the 20 hour capacity rating (C20))
a) After inserting the fuse the display will show the scrolling text
01 BATTERY CAPACI TY
If this text is not shown, press SETUP and SELECT simultaneously during 3
seconds to restore factory settings or go to section 4 for full setup details
(setting 64, Lock setup, must be OFF to restore factory settings, see
section 4.2.5).
b) Press any button to stop scrolling and the factory default value 0200 Ah
will appear in edit mode: the first digit will blink.
Enter the desired value with the + and buttons.
c) Press SELECT to set the next digit in the same manner.
Repeat this procedure until the required battery capacity is displayed.
The capacity is automatically stored in non-volatile memory when the last
digit has been set by pressing SELECT. This is indicated with a short
beep.
If a correction has to be made, press SELECT again and repeat the
procedure.
d) BMV-700 and 700H: press SETUP or + or to end the setup wizard and
switch to normal operating mode.
BMV-702: press SETUP or + or to proceed to auxiliary input setting.
1.2 Auxiliary input (BMV-702 and -712 only)
a) The display will show AUXI LI ARY I NPUT scrolling.
b) Press SELECT to stop scrolling and the LCD will show: st ar t
Use the + or key to select the required function of the auxiliary input:
START for monitoring the starter battery voltage.
MI D for monitoring the mid-point voltage of a battery bank.
TEMP for using the optional temperature sensor
Press SELECT to confirm. Confirmation is indicated with a short beep.
c) Press SETUP or + or to end the setup wizard and switch to normal
operating mode.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Victron batterij monitor BMV 712 Smart at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Victron batterij monitor BMV 712 Smart in the language / languages: English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 2.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info