Umformer typ IV60012, IV60024, IV100012, IV100024, IV150012, IV150024, IV200012, IV200024, IV300012, IV300024
DEUTSCH
4.6 Einstellungen
MitdenDIP-SchalternkönnendieEigenschaftendesUmformers
eingestellt werden.
Die DIP-Schalter befinden sich an der Seitenfche des
Umformers. Vgl. unter ‘10 Anschlusszeichnung’ Nr. 7.
Hinweis: Der Powersave-Modus kann unabhängig von der
Einstellung der DIP-Schalter über die Schalttafel ein- und aus-
geschaltet werden.
S1 S2 Functie
Landstrom
vorhanden?
Stand des
Umschalt-
relais
Ausgangsspan-
nung wird
ge liefert durch:
Umschaltzeit
bei Ausfall des
Land stroms
Powersave-
Funktion
OFF OFF DC/AC OUT MODE
JA 1 Umformer
n.z. Ausgeschaltet
NEIN 1 Umformer
OFF ON
DC/AC + POWER SAVING
MODE
JA 1 Umformer
n.z. Eingeschaltet
NEIN 1 Umformer
ON OFF
UPS MODE + POWER SAVE
MODE
JA 0 Landstrom
10 msec Eingeschaltet
NEIN 1 Umformer
ON ON
UPS MODE + DELAY MODE
+ POWER SAVE MODE
JA 0 Landstrom
5 sec Eingeschaltet
NEIN 1 Umformer
S3 S4
Ausgangs-
spannung
S5
Ausgangs-
frequenz
OFF OFF 240 V OFF 60 Hz
ON OFF 230 V ON 50 Hz
OFF ON 220 V
ON ON 200 V
Umschaltrelais
Umformer
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vetus IV60024 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vetus IV60024 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info