Battery charger / inverter COMBI-GAMMA
090138.02 61
minimum value will result in the minimum limit. (Note: In a parallel system, this limits
per Combi-Gamma!)
Setting Function
C1-05=0 Load Support Function is disabled.
C1-05=1
(Initial setting)
Load Support Function is enabled.
C1-06: Load Support Level
This setting is a special setting for load support mode when the Combi-Gamma is charg-•
ing and due to a sudden load, the AC IN current exceeds the AC IN Current Limit (B2-
05), the Combi-Gamma will switch to load support mode (when C1-05=1)
At that moment, the current need is unknown. The Combi-Gamma makes an assump-•
tion of the magnitude of this current. This assumption is equal to AC IN Current Limit
(B2-05) multiplied by this Load Support Level (C1-06). The default factor is two.
This will prevent the circuit breaker from tripping because current provided by the IN-•
VERTER minus the current drawn by the load is always lower than the rating of the cir-
cuit breaker. This happens, of course, when the AC IN Current Limit (B2-05) is correctly
adjusted on the circuit breaker.
If for instance in a • generator application, the circuit breaker has a higher value than the AC
IN Current Limit (B2-05)(Normal load of generator is lower than maximum peak load) and
one knows that the load which is switched on always draws a certain current, one can con-
sider to increase this factor (C1-06) to achieve better results with sudden load changes.
D Group (AC CHARGER):
D1 Group (Charger)
D1-02: Charge Curve
Setting Function
D1-02=1 Fixed
D1-02=2 Adaptive
D1-02=3
(Initial setting)
Adaptive + Battery safe
The Fixed (D1-02=1) charge curve will have a fixed • Absorption Time (D1-06).
The • Adaptive (D1-02=2) and Adaptive +Battery safe (D1-02=3) curve derive the Ab-
sorption time from the Bulk time. The maximum Absorption time of these charge curves
is determined by Absorption Time (D1-06) setting.
The • Adaptive + Battery safe (D1-02=3) curve has a special regulation in the absorption
phase. The absorption phase will start when the battery voltage reaches 14.4V( for 12V
batteries) regardless of the specified Absorption Voltage (D1-03). During the absorption
phase, the voltage will increase with a fixed ramp until the voltage reaches the absorp-
tion voltage or the calculated absorption time is over in the latter case, the absorption
phase will end before the absorption voltage is reached.
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vetus COMBI3024 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vetus COMBI3024 in the language / languages: English as an attachment in your email.

The manual is 4,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vetus COMBI3024

Vetus COMBI3024 Usermanual and installation guide - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info