661548
72
Zoom out
Zoom in
Previous page
1/80
Next page
Battery charger / inverter COMBI-GAMMA
72 090138.02
U2-04: AC IN Current
Use constant U2-04 to monitor the AC input current value in units of 0.1A when the cur-•
rent fault occurs.
U2-05: AC OUT Voltage
Use constant U2-05 to monitor the AC output voltage value in units of 0.1V when the •
current fault occurs.
U2-06: AC OUT Current
Use constant U2-06 to monitor the AC output current value in units of 0.1A when the •
current fault occurs.
U2-07: Battery Voltage
Use constant U2-07 to monitor the battery voltage value in units of 0.1V when the current •
fault occurs.
U2-08: Battery Ripple Volt
Use constant U2-08 to monitor the battery ripple voltage in units of 0.1V when the cur-•
rent fault occurs.
U2-09: Battery Current
Use constant U2-09 to monitor the battery current value in units of 0.1A when the current •
fault occurs.
U2-10: Control Mode
Use constant U2-10 to monitor what the control mode (MODE 1, MODE 2, MODE 3 or •
MODE 4) is when the current fault occurs.
U2-11: Operation Status
Use constant U2-11 to monitor 12 digits which account for each operation status when •
the current fault occurs. Please see NOTE 1 in Chapter 5.
U2-12: Aux-Relay Status
Use constant U2-12 to monitor the ON/OFF status of 3 sets of Aux-Relay (RY1, RY2, •
RY3) when the current fault occurs. Please see NOTE 2 in Chapter 5.
U2-13: Elapsed Time
Use constant U2-13 to monitor the elapsed time after power ON (O2-03=0) or after RUN •
(O2-03=1) in unit of 1 hour when the current fault occurs.
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vetus COMBI3012 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vetus COMBI3012 in the language / languages: English as an attachment in your email.

The manual is 4,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vetus COMBI3012

Vetus COMBI3012 Usermanual and installation guide - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info