2525 3-90-30007467Vermont Castings • Stardance SDDVT Installation Manual_R35 • 11/23
WARNING
Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle.
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the
rebox, to conrm that you have the appropriate rebox
for the type of fuel to be used. The Stardance may be
converted from one gas to another using the appropriate
Fuel Conversion Kit.
In the U.S.; Gas connection should be made in accordance
with current National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Since some municipalities have additional local codes, be
sure to consult your local authority.
In Canada; consult the local authority and CSA-B149.1
installation code.
NOTE: Always check for gas leaks with a mild soap and
watersolution.Donotuseanopenameforleaktesting.
Light the pilot according to the directions in the Operation
section of this manual.
Burner Information
The appliance must only use the gas specied on the rating
plate, unless converted using a Vermont Castings Fuel
Conversion Kit.
THIS APPLIANCE SHOULD BE CONNECTED TO THE
GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE
TECHNICIAN. FOLLOW ALL LOCAL CODES.
THERE MUST BE A GAS SHUT-OFF BETWEEN THE
STOVE AND THE SUPPLY.
CAUTION
This appliance should only be connected by a qualied gas
technician. Test to conrm manifold pressures as specied
below.
The Stardance Heater and its individual shuto󰀨 valve must
be disconnected from the gas supply piping during any
pressure testing of that system at test pressures in excess
of 1/2 psig (3.5 kPa).
The Stardance Heater must be isolated from the gas supply
piping system by closing its individual manual shuto󰀨 valve
during any pressure testing of the gas supply piping system
at test pressure equal to or less than 1/2 psig.
There must be a gas shuto󰀨 between the stove and the
supply.
In order to connect Natural Gas, use a tting with 1/2" NPT
on the valve side and 1/2" natural gas supply line with an
input of 38,000 BTUs at a manifold pressure of 3.5" between
minimum inlet supply of 5.5" w.c. and maximum of 10.0" w.c.
In order to connect Propane, use a tting with 1/2" NPT
on the valve side and 1/2" propane gas supply line with
an input of 36,000 BTUs at a manifold pressure of 10.0"
between a minimum inlet supply of 11.0" w.c. and maximum
of 13.0" w.c.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Stardance Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Stardance Series in the language / languages: English as an attachment in your email.

The manual is 7.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Stardance Series

Vermont Castings Stardance Series User Manual - French - 54 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info