Vermont Castings • Intrepid FlexBurn® Owner’s Manual_R22 • 2018 - ___ • 08/2312 3-90-30007345C
Surface Thermometer is a Valuable Guide to Operation
An optional surface thermometer tells you when to adjust
the air control, and when to refuel. (Figure 2.8)
Figure 2.8-Taketemperaturereadingswithathermometerlocated
in the middle of the griddle.
For example, when the thermometer registers at least
450°F(230°C)onthestovetopafterstart-upyouknowthe
stove is hot enough and it may be time to close the damper
ifasu󰀩cientemberbedhasalsobeenestablished.Note
that the stove will warm up much sooner than the chimney,
though;awarmchimneyisthekeytoeasy,e󰀨ectivestove
operation.Whenthermometerreadingsdropbelow350°F.
(175°C)it’stimetoadjusttheaircontrolforahigherburn
rateortoreloadthestove.Atemperaturereadingover650°F
(340°C)whenthedamperisclosedisasigntoreducethe
air supply to slow the burn rate.
Usethefollowingtemperaturerangesasaguide:
• Readingsinthe350°-500°F.(175°-260°C)rangeindicate
low to medium heat output.
• 500°-600°F. (260°-315°C) readings indicate medium
heat output.
• Readingsof600°-650°F.(315-340°C)indicatehighheat
output. Operating your Intrepid FlexBurn® continuously
atgriddletemperatureshigherthan650°F(340°C)may
damagethecastironorenamelnish.
Use the Air Control Settings that Work Best for You
No single air control setting will t every situation. Each
installation will di󰀨er depending on the quality of the fuel,
theamountofheatdesired,andhowlongyouwishthere
to burn; outdoor air temperature and pressure also a󰀨ect
draft.
The control setting also depends on your particular
installation’s “draft,” or the force that moves air from the
stove up through the chimney. Draft is a󰀨ected by such
things as the length, type, and location of the chimney, local
geography, nearby obstructions, and other factors.
Toomuchdraft maycauseexcessivetemperatures inthe
IntrepidFlexBurn®,andcouldevendamagethestove.On
theotherhand,toolittledraftcancausebackpu󰀩ngintothe
roomand/orthe“plugging”ofthechimney.
Howdoyouknowifyourdraftisexcessivelyhighorlow?
Symptoms of too much draft include an uncontrollable
burn or a glowing-red stove part. Signs of weak draft are
smokeleakingintotheroomthroughthestoveorchimney
connector joints or low heat output.
Insomenewerhomesthatarewell-insulatedandweather-
tight, poor draft may result from an insu󰀩cient air supply
inthehouse.Insuchinstances,anopenwindownearthe
stove on the windward side of the house can provide the
combustion air supply needed.
Another option for getting more combustion air to the stove
is to duct air directly from outside to the stove. In some
areas provisions for outside combustion air are required in
all new construction.
When rst using the stove, keep track of the air control
settings.Youwillquicklyndthataspecicsettingwillgive
youaxed amountofheat.It maytakeaweek ortwoto
determine the amount of heat and the length of burn you
shouldexpectfromvarioussettings.
Most installations do not require a large amount of
combustion air, especially if adequate draft is available.
Donotforanyreasonattempttoincreasetheringofyour
heater by altering the air control adjustment range outlined
in these directions.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Intrepid FlexBurn at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Intrepid FlexBurn in the language / languages: English as an attachment in your email.

The manual is 10.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Intrepid FlexBurn

Vermont Castings Intrepid FlexBurn User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info