815503
6
Zoom out
Zoom in
Previous page
1/28
Next page
Vermont Castings • Intrepid FlexBurn® Owner’s Manual_R22 • 2018 - ___ • 08/23 63-90-30007345C
A. Appliance Certication
C. Mobile Home Approved (USA ONLY)
This appliance is approved for mobile home installations
in the USA when not installed in a sleeping room and
when an outside combustion air inlet is provided.
Thestructuralintegrityofthemobilehomeoor,ceiling,
and walls must be maintained.
The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
chimneymustbelistedtoUL103HToralistedUL-1777
fulllengthsixinch(152mm)diameterlinermustbeused.
Outside air must be provided in a mobile home
installation.
• Mobilehomebracketkit#0003264mustbeinstalled.
D. Glass Specications
This appliance is equipped with 5mm ceramic glass.
Replaceglassonlywith5mmceramicglass.Pleasecontact
your dealer for replacement glass.
E. California Safety Information
B. BTU & E󰀩ciency Specications
MODEL: IntrepidFlexBurn® 2115/2115-CAT
LABORATORY: OMNITestLaboratories,Inc
REPORT NO. 0135WS038S/0135WS038E
TYPE: SolidFuelTypeRoomHeaters
STANDARD(s): UL1482,ULC-S627-00
EPA Report #: 114-18(without catalyst)
115-18(catalytic)
EPA Certied Emissions: .6 g/hr (without catalyst)
.3 g/hr (catalytic)
*LHV Tested E󰀩ciency: 80.3%(without catalyst)
82.8%(catalytic)
**HHV Tested E󰀩ciency: 74.3%(without catalyst)
76.7%(catalytic)
***EPA BTU Output:
12,500-18,500
(without catalyst)
10,700-16,000
(catalytic)
****Peak BTU/Hour Output: 36,900 (without catalyst)
34,900 (catalytic)
Vent Size: 6Inch(152mm)
Firebox Size: 1.31 cu. ft.
Recommended Length: 14”
Max. Wood Length: 15”
Fuel Orientation: East,West
Fuel SeasonedCordwood
(20%moisture)
* Weighted average LHV e󰀩ciency using Douglas Fir
dimensional lumber and data collected during EPA
emissions test.
**Weighted average HHV e󰀩ciency using Douglas
Fir dimensional lumber and data collected during EPA
emissions test.
***E󰀩cienciesarebasedontestresultscalculatedusing
B415; these calculated e󰀩ciencies are then used to
calculateoutputBTU’s.
****ApeakBTUoutoftheappliancecalculatedusingthe
maximumrsthourburnratefromtheHighEPATestand
theBTUcontentofcordwood(8600)timesthee󰀩ciency.
1 1 Product Specic and Important Safety Information
This wood appliance needs periodic inspection and repair for
properoperation.Itisagainstfederalregulationstooperate
this wood appliance in a manner inconsistent with operating
instructions in this manual.
The Vermont Castings Intrepid FlexBurn®
WoodAppliancemeetstheU.S.Environmental
Protection Agency’s crib wood emission limits
forwoodappliancessoldafterMay15,2020.
WARNING
This product and the fuels used to operate this product
(wood), and the products of combustion of such fuels, can
expose you to chemicals including carbon black, which
isknowntotheStateofCaliforniatocause cancer,and
carbonmonoxide,whichisknowtotheStateofCalifornia
to cause birth defects or other reproductive harm. For
more information go to: www.P65Warnings.ca.gov
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermont Castings Intrepid FlexBurn at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermont Castings Intrepid FlexBurn in the language / languages: English as an attachment in your email.

The manual is 10.81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Vermont Castings Intrepid FlexBurn

Vermont Castings Intrepid FlexBurn User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info