E
SQUOD_SU
06/2009
10
L Make sure that no objects, persons or body parts are inside the movement range of the
upright function, since this could cause damage or injury.
BATTERY CHARGER
To charge the batteries, only use the battery charger supplied - IMPULSE S (8 A).
Primary voltage
230 Vac – 50/60 Hz – single phase
Secondary nominal voltage
24 V
Secondary maximum voltage
35 V
Secondary power
max. 8 A
Battery type
Lead-sulphuric acid: gel
Battery capacity
60 Ah – 85 Ah (80% capacity charged within 8 hours)
Safeguards
Protected against reverse polarisation, electrical
surges and extreme temperature
Nominal output
270 W
Efficiency
min. 80% (when fully loaded)
Ambient temperature
0° C to +40° C
Unit dimensions
H 70 x W 150 x D 200 mm
Protection range
IP 21, Protection Class II
Total weight
Approx. 1.3 kg
Mains cable length
1.9 m
Charge cable length
2.4 m
Ambient storage temperature
-15° C to +50° C
Relative storage humidity
max. 95% (non-condensing)
Conformity
EMC Directive 89/336/EEC
Low Voltage Directive 73/23/EEC
We reserve the right to introduce technical changes.
CHARGING THE BATTERIES
As the IMPULSE S (8 A) charger aligns the charge curve with the AGM batteries' charge level, you
can recharge your wheelchair after each use. This avoids any aggressive battery charging and the
"memory effect".
Recharge the wheelchair, at the latest, when the charge indicator on the steering unit goes into the red
zone. If, despite this, you continue driving, eventually only the last red diode lights up and flashes
continually, indicating that the batteries are nearly flat. If you disregard this warning signal, too, an
error message will shortly appear indicating that the batteries can no longer provide power for driving.
The batteries should therefore be charged before these error messages appear, using the supplied
battery charger IMPULSE S (8 A). Avoid the batteries becoming drained, in any case.
SETTING UP THE CHARGER
When setting up the charger, ensure that it is well-ventilated on all sides. A minimum of 10 cm space
should be left free around the unit for this purpose. If the charger is insufficiently ventilated so that the
unit heats up, the charging rate will fall which will extend the charging time. If the charger overheats (>
+50° C), it will stop charging.
The charger should only be used from a wall socket with a voltage of 230V 50/60Hz and in well-
ventilated, dry areas.
FIRST USE
First put the plug into the wall socket. After an LED combination has lit up, the charger switches to
STANDBY. Both LEDs (green and yellow) are active.
Next, connect the charger cable with the three-pin plug to the loader socket on the electric
wheelchair's steering unit. Once connected to the batteries, the charger automatically begins charging.
Now only the yellow LED is active.
When charging is complete, the yellow LED goes out and the green LED comes on. Now remove the
charger cable from the steering unit. The charger switches back to STAND-BY mode (yellow and
green LEDs active).
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Vermeiren Squod SU at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Vermeiren Squod SU in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info