689148
29
Zoom out
Zoom in
Previous page
1/68
Next page
23ENVenta Comfort
Plus
English
WHAT HAPPENS IF?
Ensure that the device is switched o during any measures and the
switching power supply is disconnected from the outlet!
... E1 is shown in the display?
The device has switched o automatically because the locking buttons on the
upper housing are not closed properly.
i
Close upper housing properly again by pushing on the outer ends of locking buttons.
Switch device on and o with the power button
.
... E2 is shown in the display?
The device has switched o automatically, because the motor is overstrained
(e.g. through the intrusion of foreign objects or similar).
i
Measure: Remove upper housing. Check whether the disk stack in the lower housing as
well as fan blades in the upper housing are freely movable. Next, place the device back in
operation.
... the display is touched with stronger pressure?
This can result in visible „pressure points“, which does not represent a quality
defect. After the pressure is removed, these „pressure points“ will disappear.
... the power button to switch on the device does not appear in the
display?
Please check whether the switching power supply is connected to the mains.
... the power button to switch on the device does not appear in the
display, even though the switching power supply is connected to the
mains?
Please check whether the switching power supply is rmly plugged into the drive
unit
i
Measure: Remove upper housing. Check correct seating (see instructions to clean the
upper housing of the device). Next, place the device back in operation.
... WATER is shown in the display, even though there is water in the
lower housing?
Please check whether there is sucient water in the lower housing and/or
whether the upper housing is placed correctly on the lower housing.
i
Measure: Remove upper housing. Fill lower housing with tap water to the WATERLINE
marking. Place upper housing correctly on lower housing. The switching power supply
may not be jammed between the upper and lower housings. Next, place the device back
in operation.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Venta LW15 COMFORT Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Venta LW15 COMFORT Plus in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info