DVM894
V. 01 21/01/2015 8 ©Velleman nv
Input socket
COM
common inut terminal
V, Ω, Hz
TEMP
input terminal for all other measurements
mA
hFE
input terminal for transistor, capacitance, and current
measurements
10A
input terminal for currents between 200 mA and 10 A
7. Use
7.1 Preparation
1. Switch on the meter by turning the rotary switch. If the battery voltage is
lower than 7 V, the low-battery symbol will appear and the batteries should
be replaced.
2. The warning symbol next to the input lead shows that the input voltage or
current should not exceed the specified value in order to protect the internal
circuit from damage.
3. Turn the rotary switch to the required function and range to be measured.
4. Choose the highest range when the value to be measured is unknown.
5. When making connection, connect the common test lead first and then the
powered test lead.
6. Remove the charged test lead first when disconnecting.
7.2 Readings Hold
1. Press HOLD to hold the reading of the current measurements.
2. Press HOLD again to release the reading.
7.3 AC/DC Voltage Measurement
USE CAUTION WHEN MEASURING HIGH-VOLTAGE CIRCUITS TO AVOID
ELECTRICAL SHOCK AND INJURY. DO NOT TEST VOLTAGES HIGHER THAN
600 V AC/DC.
1. Plug the black test lead into the COM jack and the red test lead into the
VTempΩ Hz jack.
2. Set the rotary switch to the V position for DC measurement and V for AC
measurement. Select the proper range.
3. Connect the test leads to the voltage source or load for measurement.
4. Read the value on the main indicator of the LCD. The polarity symbol denotes
the polarity of the end connected by the red test lead.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Velleman DVM894 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Velleman DVM894 in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 1,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info